18 Years Factory Diabetes Test Strips - colloidal gold adenovirus one step av test kit AV rapid test for Kid – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate inside our success for Dengue Iggigm Rapid Test Strip , Colloidal Gold Rapid Test Hiv , Chlamydia Rapid Home Test , Therefore, we can meet different inquiries from different consumers. You should find our web page to check additional info from our products.
18 Years Factory Diabetes Test Strips - colloidal gold adenovirus one step av test kit AV rapid test for Kid – Baysen Detail:

Products Parameters

3.AV

PRINCIPLE AND PROCEDURE

PRINCIPLE

The membrane of the test device is coated with Rotavirus Group A antigen on the test region and goat anti rabbit IgG antibody on the control region. Lable pad are coated by fluorescence labeled anti Rotavirus Group A and rabbit IgG in advance. When testing positive sample, the RV in sample combine with fluorescence labeled anti Rotavirus Group A, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper. When complex passed the test region, it combined with anti-Rotavirus Group A coating antibody, forms new complex. If it is negative, there is no Rotavirus Group A antigen in the sample, so that immune complexes cannot be formed, there will be no red line in the detection area (T). Regardless of whether group A rotavirus is present in the specimen, the latex-labeled mouse IgG is chromatographed to the quality control area (C) and captured by goat anti-mouse IgG antibody. A red line will appear in the quality control area (C). The red line is the standard appears in the quality control area (C) for judging whether there are enough samples and whether the chromatography process is normal. It is also used as an internal control standard for reagents.

Test Procedure:

1.Symptomatic patients should be collected. According to reports, the maximum excretion of rotavirus in the faeces of patients with gastroenteritis occurs 3-5 days after the begin of the disease and 3-13 days after the start of symptoms. If the sample is collected long after the diarrhea, the number of antigens may not be enough to occur the positive reaction.

2.The samples should be collected in a clean, dry, waterproof container which does not contain detergents and preservatives.

3.For non-diarrhea patients, the collected faeces samples should not be less than 1-2 grams. For patients with diarrhea, if the faeces is liquid, please collect at least 1-2 ml of faeces liquid. If the faeces contains a lot of blood and mucus, please collect the sample again.

4.It is recommended to test the samples immediately after collection, otherwise they should be sent to the laboratory within 6 hours and stored at 2-8°C. If the samples have not been tested within 72 hours, they should be stored at the temperature below -15°C.

5.Use fresh feces for testing, and faeces samples mixed with diluent or distilled water

packing

You May like


Home used SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


WIZ-A101 Portable Immune Analyzer


WIZ-A101 Portable Immune Analyzer


6.超级链接产品第三个产品的图片rv


Diagnostic Kit for Rotavirus Group A (Colloidal Gold)

About Us

贝尔森主图_conew1

Xiamen Baysen Medical Tech limited is a high biological enterprise which devotes itself to filed of fast diagnostic reagent and integrates research and development, production and sales into a whole. There are many advanced research staffs and sales managers in the company, all of them are have rich working experience in china and international biopharmaceutical enterprise.

Certificate display

dxgrd


Product detail pictures:

18 Years Factory Diabetes Test Strips - colloidal gold adenovirus one step av test kit AV rapid test for Kid – Baysen detail pictures

18 Years Factory Diabetes Test Strips - colloidal gold adenovirus one step av test kit AV rapid test for Kid – Baysen detail pictures

18 Years Factory Diabetes Test Strips - colloidal gold adenovirus one step av test kit AV rapid test for Kid – Baysen detail pictures


Related Product Guide:
Weekly Dose: Keytruda may be a miracle cancer drug, but can those who need it afford it? | P24 Test Strips
Four reasons I won’t have a prostate cancer blood test | Cpn-Igm

We thinks what buyers think, the urgency of urgency to act during the interests of a purchaser position of theory, allowing for much better high-quality, reduced processing costs, charges are more reasonable, won the new and outdated consumers the support and affirmation for 18 Years Factory Diabetes Test Strips - colloidal gold adenovirus one step av test kit AV rapid test for Kid – Baysen , The product will supply to all over the world, such as: Borussia Dortmund, Swaziland, Slovakia, We have gained a lot of recognition among customers spread all across the world. They trust us and always give repetitive orders. Furthermore, mentioned below are some of the major factors that have played significant role in our tremendous growth in this domain.
  • The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Althea from Swiss - 2015.06.19 10:42
    The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
    5 Stars By Natividad from Lyon - 2015.08.12 12:27