Our firm since its inception, normally regards item top quality as company life, constantly make improvements to generation technology, improve product excellent and repeatedly strengthen organization total good quality management, in strict accordance with the national standard ISO 9001:2000 for Rapid Test Hbsag Hcv , Fob (Fecal Occult Blood) , Health Analyzer Machine , We sincerely welcome overseas customers to consult for the long-term cooperation and the mutual development.We strongly believe that we can do better and better.
China wholesale Rapid Diagnostic H Pylori Test Kit - Diagnostic Kit for Isoenzyme MB of Creatine Kinase(fluorescence immunochromatographic assay) – Baysen Detail:

Diagnostic Kit for Isoenzyme MB of Creatine Kinase(fluorescence immunochromatographic assay)
For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE
Diagnostic Kit for Isoenzyme MB of Creatine Kinase(fluorescence immunochromatographic assay) is a fluorescence immunochromatographic assay for the quantitative detection of Isoenzyme MB of Creatine Kinase (CK-MB) in human serum or plasma, it is used for auxiliary diagnosis of AMI(Acute Myocardial Infarction). All positive sample must be confirmed by other methodologies. This test is intended for healthcare professional use only.

SUMMARY
CK-MB levels increased 4-6 hours after Myocardial infarction occurred, peaked at 18-24 hours, and returned to normal 2-3 days later. CK-MB release into circulation later than hemoglobin.CK-MB is the traditional marker of acute myocardial infarction

PRINCIPLE OF THE PROCEDURE
The membrane of the test device is coated with anti CK-MB antibody on the test region and goat anti rabbit IgG antibody on the control region. Lable pad are coated by fluorescence labeled anti CK-MB antibody and rabbit IgG in advance. When testing positive sample, the CK-MB antigen in sample combine with fluorescence labeled anti CK-MB antibody, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper, when complex passed the test region, it combined with anti CK-MB coating antibody, forms new complex. CK-MB level is positively correlated with fluorescence signal, and the concentration of CK-MB in sample can be detected by fluorescence immunoassay assay.

REAGENTS AND MATERIALS SUPPLIED

25T package components
Test card individually foil pouched with a desiccant 25T
Sample diluents 25T
Package insert 1

MATERIALS REQUIRED BUT NOT PROVIDED
Sample collection container,timer

SAMPLE COLLECTION AND STORAGE
1.The samples tested can be serum, heparin anticoagulant plasma or EDTA anticoagulant plasma.

2.According to standard techniques collect sample. Serum or plasma sample can be kept refrigerated at 2-8℃ for 7days and cryopreservation below -15°C for 6 months.
3.All sample avoid freeze-thaw cycles.

ASSAY PROCEDURE
Please read the instrument operation manual and package insert before testing.

1.Lay aside all reagents and samples to room temperature.
2.Open the Portable Immune Analyzer(WIZ-A101), enter the account password login according to the operation method of the instrument, and enter the detection interface.
3.Scan the dentification code to confirm the test item.
4.Take out the test card from the foil bag.
5.Insert the test card into the card slot, scan the QR code, and determine the test item.
5.Add 40μL serum or plasma sample to sample diluent, and mix well..
6.Add 80μL sample solution to sample well of the card.
7.Click the “standard test” button, after 15 minutes, the instrument will automatically detect the test card, it can read the results from the display screen of the instrument, and record/print the test results.
8.Refer to the instruction of Portable Immune Analyzer(WIZ-A101).

EXPECTED VALUES
CK-MB <5ng/mL

It is recommended that each laboratory establish its own normal range representing its patient population.

TEST RESULTS AND INTERPRETATION
.The above data is the result of CK-MB reagent test, and it is suggested that each laboratory should establish a range of CK-MB detection values suitable for the population in this region. The above results are for reference only.

.The results of this method are only applicable to the reference ranges established in this method, and there is no direct comparability with other methods.
.Other factors can also cause errors in detection results, including technical reasons, operational errors and other sample factors.

STORAGE AND STABILITY
1.The kit is 18 months shelf-life from the date of manufacture. Store the unused kits at 2-30°C. DO NOT FREEZE. Do not use beyond the expiration date.

2.Do not open the sealed pouch until you are ready to perform a test, and the single-use test is suggested to be used under the required environment (temperature 2-35℃, humidity 40-90%) within 60 mins as quickly as possible.
3.Sample diluent is used immediately after being opened.

WARNINGS AND PRECAUTIONS
.The kit should be sealed and protected against moisture.

.All positive specimens shall be validated by other methodologies.
.All specimens shall be treated as potential pollutant.
.DO NOT use expired reagent.
.DO NOT interchange reagents among kits with different lot No..
.DO NOT reuse test cards and any disposable accessories.
.Misoperation, excessive or little sample can lead to result deviations.

LIMITATION
.As with any assay employing mouse antibodies, the possibility exists for interference by human anti-mouse antibodies (HAMA) in the specimen. Specimens from patients who have received preparations of monoclonal antibodies for diagnosis or therapy may contain HAMA. Such specimens may cause false positive or false negative results.

.This test result is only for clinical reference, should not serve as the only basis for clinical diagnosis and treatment, the patients clinical management should be comprehensive consideration combined with its symptoms, medical history, other laboratory examination, treatment response, epidemiology and other information.
.This reagent is only used for serum and plasma tests. It may not obtain accurate result when used for other samples such as saliva and urine and etc.

PERFORMANCE CHARACTERISTICS

Linearity 0.5ng/mL to 80ng/mL relative deviation:-15% to +15%.
Linear correlation coefficient:(r)≥0.9900
Accuracy The recovery rate shall be within 85% – 115%.
Repeatability CV≤15%
Specificity(None of the substances at the interferent tested interfered in the assay)

Interferent

Interferent concentration

sTnI

1000μg/L

cTnT

1000μg/L

ABP

1000μg/L

cTnI

1000μg/L

cTnC

1000μg/L

sTnT

1000μg/L

MYO

1000μg/L

REFERENCES
1.Hansen JH,et al.HAMA Interference with Murine Monoclonal Antibody-Based Immunoassays[J].J of Clin Immunoassay,1993,16:294-299.

2.Levinson SS.The Nature of Heterophilic Antibodies and the Role in Immunoassay Interference[J].J of Clin Immunoassay,1992,15:108-114.

Key to symbols used:

 t11-1 In Vitro Diagnostic Medical Device
 tt-2 Manufacturer
 tt-71 Store at 2-30℃
 tt-3 Expiration Date
 tt-4 Do Not Reuse
 tt-5 CAUTION
 tt-6 Consult Instructions For Use

Xiamen Wiz Biotech CO.,LTD
Address:3-4 Floor,NO.16 Building,Bio-medical Workshop,2030 Wengjiao West Road,Haicang District,361026,Xiamen,China
Tel:+86-592-6808278
Fax:+86-592-6808279


Product detail pictures:

China wholesale Rapid Diagnostic H Pylori Test Kit - Diagnostic Kit for Isoenzyme MB of Creatine Kinase(fluorescence immunochromatographic assay) – Baysen detail pictures

China wholesale Rapid Diagnostic H Pylori Test Kit - Diagnostic Kit for Isoenzyme MB of Creatine Kinase(fluorescence immunochromatographic assay) – Baysen detail pictures


Related Product Guide:
PSA Test Market Research With Industry Segments, Characteristics and Size With Forecast By 2023 | Cpn-Igm
Silencing MicroRNA-155 Attenuates Cardiac Injury and Dysfunction in Viral Myocarditis via Promotion of M2 Phenotype Polarization of Macrophages | Calprotectin Elisa Kit

Our aim is usually to give superior quality items at aggressive rates, and top-notch company to clients around the earth. We have been ISO9001, CE, and GS certified and strictly adhere to their good quality specifications for China wholesale Rapid Diagnostic H Pylori Test Kit - Diagnostic Kit for Isoenzyme MB of Creatine Kinase(fluorescence immunochromatographic assay) – Baysen , The product will supply to all over the world, such as: Detroit, Los Angeles, Libya, With the spirit of "high quality is our company's life; good reputation is our root", we sincerely hope to cooperate with customers from at home and abroad and hope to build a good relationship with you.
  • In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
    5 Stars By Elsie from belarus - 2016.03.28 16:34
    After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
    5 Stars By Elsa from Chile - 2015.09.29 17:23
    Write your message here and send it to us