Quality First,and Customer Supreme is our guideline to provide the best service to our customers.Nowadays, we are trying our best to become one of the best exporters in our field to meet customers more need for Diagnostic Kit For Testosterone , Nt Probnp Test Kit , Psa Test Cost , Welcome all nice buyers communicate details of solutions and ideas with us!!
Europe style for Medical Device Rapid Test - Diagnostic Kit(LATEX)for Rotavirus Group A – Baysen Detail:

Diagnostic KitLATEXfor Rotavirus Group A
For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE
Diagnostic Kit(LATEX)for Rotavirus Group A is suitable for qualitative detection of Rotavirus Group A antigen in human fecal samples. This test is intended for healthcare professional use only. Meanwhile, this test is used for the clinical diagnosis of infantile diarrhea in patients with Rotavirus Group A infection.

PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 50 kits /box.

SUMMARY
Rotavirus is classified as a rotavirus genus of the exenteral virus, which has a spherical shape with a diameter of about 70nm. Rotavirus contains 11 segments of double-stranded RNA. The rotavirus can be seven groups (a-g) based on antigenic differences and gene characteristics. Human infections of group A, group B and C group rotavirus have been reported. Rotavirus Group A is the important cause of severe gastroenteritis in children worldwide[1-2].

ASSAY PROCEDURE
1.Take out the sampling stick, inserted into the faeces sample, then put the sampling stick back, screw tight and shake well, repeat the action 3 times. Or using the sampling stick picked about 50mg faeces sample, and put in a faeces sample tube containing sample dilution, and screw tightly.

2.Use disposable pipette sampling take the thinner faeces sample from the diarrhea patient, then add 3 drops (about 100uL) to the fecal sampling tube and shake well, put aside.
3.Take out the test card from the foil bag, put it on the level table and mark it.
4.Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample verticaly and slowly into sample well of the card with provided dispette, start timing.
5.The result should be read within 10-15 minutes, and it is invalid after 15 minutes.
w

 


Product detail pictures:

Europe style for Medical Device Rapid Test - Diagnostic Kit(LATEX)for Rotavirus Group A – Baysen detail pictures


Related Product Guide:
OPKO’s Prostate Cancer Test A $2 Billion Market Opportunity | Psa Test Cost
New Study Shows MDxHealth’s SelectMDx Test is Cost-Effective for Biopsy Selection Brussels Stock Exchange:MDXH | Cpn-Igm

Sticking towards the principle of "Super High-quality, Satisfactory service" ,We've been striving to become a superb business partner of you for Europe style for Medical Device Rapid Test - Diagnostic Kit(LATEX)for Rotavirus Group A – Baysen , The product will supply to all over the world, such as: Sweden, Vietnam, Oman, We insist on the principle of "Credit being primary, Customers being the king and Quality being the best", we are looking forward to the mutual cooperation with all friends at home and abroad and we will create a bright future of business.
  • We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Claire from Macedonia - 2016.02.14 13:19
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Donna from Belgium - 2016.08.16 13:39