Factory best selling Braun Ear Thermometer - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

Sticking for the basic principle of "Super Top quality, Satisfactory service" ,We've been striving to be an excellent business enterprise partner of you for Diagnostic Kit Creatine Kinase , Fecal Occult Blood Rapid Testing Strip , Crp Rapid Test Strips , Our mission is to allow you to create long-lasting relationships together with your consumers via the ability of marketing merchandise.
Factory best selling Braun Ear Thermometer - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen Detail:

Products Parameters

3.TF-2

PRINCIPLE AND PROCEDURE OF FOB TEST

PRINCIPLE

The membrane of the test device is coated with Tf antibody on the test region and goat anti rabbit IgG antibody on the control region. Lable pad are coated by fluorescence labeled anti Tf antibody and rabbit IgG in advance. When testing positive sample, the Tf antigen in sample combine with fluorescence labeled anti Tf antibody, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper. When complex passed the test region, it combined with anti Tf coating antibody, forms new complex.

If it is negative, the sample does not contain transferrin or the content is low, so that the immune complex cannot be formed. There will be no red line in the detection area (T). No matter whether Tf antibody exists in the specimen or not, the remaining colloidal gold-labeled mouse anti-human IgM monoclonal antibody and the goat anti-mouse IgG antibody coated in the quality control area (C) line. Then the agglutinates develop color in the quality control area, and the red line will appear in (C). The red line is the standard appears in the quality control area (C) for judging whether there are enough samples and whether the chromatography process is normal. It is also used as an internal control standard for reagents.

Test Procedure

Please read the package insert before testing.

1.Take out the test card from the foil bag, put it on the level table and mark it.

2.Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample vertically and slowly into sample well of the card with provided dispette. Then start the timer.

packing

You May like


Home used SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


WIZ-A101 Portable Immune Analyzer


WIZ-A101 Portable Immune Analyzer


6.超级链接产品第三个产品的图片cal


Diagnostic Kit for calprotectin (Colloidal Gold)

About Us

贝尔森主图_conew1

Xiamen Baysen Medical Tech limited is a high biological enterprise which devotes itself to filed of fast diagnostic reagent and integrates research and development, production and sales into a whole. There are many advanced research staffs and sales managers in the company, all of them are have rich working experience in china and international biopharmaceutical enterprise.

Certificate display

dxgrd


Product detail pictures:

Factory best selling Braun Ear Thermometer - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures

Factory best selling Braun Ear Thermometer - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures

Factory best selling Braun Ear Thermometer - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures

Factory best selling Braun Ear Thermometer - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures

Factory best selling Braun Ear Thermometer - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures

Factory best selling Braun Ear Thermometer - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures

Factory best selling Braun Ear Thermometer - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures


Related Product Guide:
Evalúan uso de pruebas POC para la calprotectina fecal – Química Clínica | Psa Test Cost
Commutability of the First World Health Organization International Standard for Human Cytomegalovirus | Cpn-Igm

Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" as well as the theory of "quality the basic, believe in the 1st and management the advanced" for Factory best selling Braun Ear Thermometer - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen , The product will supply to all over the world, such as: Sierra Leone, Naples, Ghana, If you give us a list of products you are interested in, along with makes and models, we can send you quotations. Please email us directly. Our goal is to establish long-term and mutually profitable business relationships with domestic and overseas clients. We look forward to receiving your reply soon.
  • The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Andy from Greece - 2015.07.26 16:51
    The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
    5 Stars By Clementine from Cairo - 2016.01.28 19:59