FIA Antibody To Thyroglobulin Tg-ab Test For Autoimmune Thyroiditis

short description:

Diagnostic Kit for Antibody to Thyroglobulin 

Methodology: Fluorescence Immunochromatographic Assay

 


  • Testing time: 10-15 minutes
  • Valid Time: 24 month
  • Accurancy: More than 99%
  • Specification: 1/25 test/box
  • Storage temperature : 2℃-30℃
  • Methodology: Fluorescence Immunochromatographic Assay
  • Product Detail

    Product Tags

    Production information

    Model Number Tg-ab Packing 25 Tests/ kit, 30kits/CTN
    Name Diagnostic Kit for Antibody to Thyroglobulin Instrument  classification Class II
    Features High sensitivity, Easy opeation Certificate CE/ ISO13485
    Accuracy > 99% Shelf life Two Years
    Methodology Fluorescence Immunochromatographic Assay
    OEM/ODM service Avaliable

     

    FT4-1

    Summary

    Thyroglobulin (Tg) is produced by thyroid gland, and its major component of thyroid follicular cavity. In synergy with thyroid-specific peroxidase (TPO), Tg has an essential function in the iodination of L-tyrosine and synthesis of thyroid hormones of T4 and T3. Tg is a potential autoantigen and rise in concentration of antibody to Thyroglobulin (Tg autoantibody) is commonly seen in thyroiditis caused by some autoimmune diseases.

     

    Feature:

    •  High sensitive

    •  result reading in 15 minutes

    •  Easy operation

    • Factory direct price

    •  need  machine for result reading

    FT4-3

    Intended Use

    This kit is applicable to in vitro quantitative detection of anti-thyroglobulin antibody (Tg-Ab) in human whole blood, serum, and plasma sample, which’s suitable for auxiliary diagnosis of thyroiditis caused by autoimmune disease. This kit only provides test results of anti-thyroglobulin antibody (Tg-Ab), and results obtained shall be used in combination with other clinical information for analysis. It must only be used by healthcare professionals.

    Test procedure

     1  Use of portable immune analyzer
     2  Open the aluminum foil bag package of reagent and take out the test device.
     3 Horizontally insert the test device into the slot of immune analyzer.
     4 On home page of operation interface of immune analyzer, click “Standard” to enter test interface.
     5 Click “QC Scan” to scan the QR code on inner side of the kit; input kit related parameters into instrument andselect sample type.Note: Each batch number of the kit shall be scanned for one time. If the batch number has been scanned, then
    skip this step.
     6  Check the consistency of “Product Name”, “Batch Number” etc. on test interface with information on the kit label.
     7  Start to add sample in case of consistent information:

     Step 1: slowly pipette 20μL serum/plasma/whole blood sample at once, and pay attention not to pipette bubbles;
     Step 2: pipette sample to sample diluent, and thoroughly mix sample with sample diluent;
     Step 3: pipette 80µL thoroughly mixed solution into well of test device and pay attention no to pipette bubbles during sampling.

     8  After complete sample addition, click “Timing” and remaining test time will be automatically displayed on theinterface.
     9  Immune analyzer will automatically complete test and analysis when test time is reached.
    10  After test by immune analyzer is completed, test result will be displayed on test interface or can be viewed through“History” on home page of operation interface.