Good Wholesale Vendors Diasnostic Kit For Alpha-Fetoprotein - Infectious HIV HCV HBSAG AND Syphilish Rapid Combo Test – Baysen
Good Wholesale Vendors Diasnostic Kit For Alpha-Fetoprotein - Infectious HIV HCV HBSAG AND Syphilish Rapid Combo Test – Baysen Detail:
PRODUCTION INFORMATION
| Model Number | HBsAg/TP&HIV/HCV | Packing | 20 Tests/ kit, 30kits/CTN |
| Name | HBsAg/TP&HIV/HCV Rapid Combo Test | Instrument classification | Class III |
| Features | High sensitivity, Easy opeation | Certificate | CE/ ISO13485 |
| Accuracy | > 97% | Shelf life | Two Years |
| Methodology | Colloidal Gold | OEM/ODM service | Avaliable |
INTENDED USE
This kit is suitable for the in vitro qualitative determination of hepatitis B virus, syphilis spirochete, human immunodeficiency virus, and hepatitis C virus in human serum/plas- ma/whole blood samples for the auxiliary diagnosis of hepatitis B virus, syphilis spirochete, human immunodeficiency virus, and hepatitis C virus infections. The results obtained should be analyzed in conjunction with other clinical information. It is intended for use by medical professionals only.
Test procedure
| 1 | Read the instruction for use and in strict conformity with instruction for use required operation to avoid affecting the accuracy of the test results |
| 2 | Before the test, the kit and the sample are taken out from thestorage condition and balanced to room temperature and mark it. |
| 3 | Tearing the packaging of the aluminum foil pouch, take out the test device and mark it, then place it horizontally on the test table. |
| 4 | Aspirate serum/plasma samples with a disposable dropper and add 2 drops in each of wells s1 and s2; add 3 drops in each of wells s1 and s2 for whole blood samples before adding 1~2 drops of rinse solution to each of wells s1 and s2 and the Timing is started |
| 5 | Test results should be interpreted within 15~20 minutes, if more than 20 min interpreted results are invalid. |
| 6 | Visual interpretation can be used in result interpretation. |
Note: each sample shall be pipetted by clean disposable pipette to avoid cross contamination.
CLINICAL PERFORMANCE
| WIZ Results ofHBsag | Test result of Reference reagent | Positive coincidence rate:99.06% (95%C.I. 96.64%~99.74%) Negative coincidence rate:98.69% (95%C.I.96.68%~99.49%) Total coincidence rate:98.84% (95%C.I.97.50%~99.47% |
||
| Positive | Negative | Total | ||
| Positve | 211 | 4 | 215 | |
| Negative | 2 | 301 | 303 | |
| Total | 213 | 305 | 518 | |
| WIZ Results ofTP | Test result of Reference reagent | Positive coincidence rate:96.18% (95%C.I. 91.38%~98.36%) Negative coincidence rate:97.67% (95%C.I.95.64%~98.77%) Total coincidence rate:97.30% (95%C.I.95.51%~98.38%) |
||
| Positive | Negative | Total | ||
| Positve | 126 | 9 | 135 | |
| Negative | 5 | 378 | 383 | |
| Total | 131 | 387 | 518 | |
| WIZ Results ofHCV | Test result of Reference reagent | Positive coincidence rate:93.44% (95%C.I. 84.32%~97.42%) Negative coincidence rate:99.56% (95%C.I.98.42%~99.88%) Total coincidence rate:98.84% (95%C.I.97.50%~99.47%) |
||
| Positive | Negative | Total | ||
| Positve | 57 | 2 | 59 | |
| Negative | 4 | 455 | 459 | |
| Total | 61 | 457 | 518 | |
| WIZ Results ofHIV | Test result of Reference reagent | Positive coincidence rate:96.81% (95%C.I. 91.03%~98.91%) Negative coincidence rate:99.76% (95%C.I.98.68%~99.96%) Total coincidence rate:99.23% (95%C.I.98.03%~99.70%) |
||
| Positive | Negative | Total | ||
| Positve | 91 | 1 | 92 | |
| Negative | 3 | 423 | 446 | |
| Total | 94 | 424 | 518 | |
Product detail pictures:
Related Product Guide:
Beyond Ben Stiller’s advice: What the experts say about PSA screening | Cpn-Igm
Repeat PSA Tests to Avoid Unnecessary Biopsies 3090D553-9492-4563-8681-AD288FA52ACE Group 2 34A8E98B-62ED-4216-98D6-E986304F4C2E | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase
Dedicated to strict high-quality management and considerate purchaser support, our experienced employees members are usually available to discuss your specifications and be certain full shopper satisfaction for Good Wholesale Vendors Diasnostic Kit For Alpha-Fetoprotein - Infectious HIV HCV HBSAG AND Syphilish Rapid Combo Test – Baysen , The product will supply to all over the world, such as: Germany, Comoros, Riyadh, Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
A good manufacturers, we have cooperated twice, good quality and good service attitude.