High Performance Level Measuring Instruments - Diagnostic Kit(LATEX)for Antigen to Helicobacter Pylori – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

With our excellent management, strong technical capability and strict quality control system, we continue to provide our clients with reliable quality, reasonable prices and excellent services. We aim at becoming one of your most reliable partners and earning your satisfaction for Rapid Kit Analyzer , Microalbuminuria , Diagnostic Kit Creatine Kinase , We focus on creating own brand and in combination with many experienced term and first-class equipment . Our goods you worth have.
High Performance Level Measuring Instruments - Diagnostic Kit(LATEX)for Antigen to Helicobacter Pylori – Baysen Detail:

Diagnostic KitLATEXfor Antigen to Helicobacter Pylori
For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE
Diagnostic Kit(LATEX)for Antigen to Helicobacter Pylori is suitable for the presence of H. Pylori antigen in human fecal samples. This test is intended for healthcare professional use only. Meanwhile, this test is used for the clinical diagnosis of infantile diarrhea in patients with HP infection.

PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 50 kits /box.

SUMMARY
H.pylori infection and chronic gastritis, gastric ulcer, gastric adenocarcinoma, gastric mucosa associated lymphoma has the close relation, in gastritis,gastric ulcer, duodenal ulcer and gastric cancer in patients with H.pylori infection rate of about 90%. The world health organization has listed HP as the first type of carcinogen and is clearly a risk factor for gastric cancer. HP detection is the important means of diagnosis of HP infection[1]. The kit is a simple and intuitive qualitative detection, detecting the helicobacter pylori in human excrement, which has high detection sensitivity and strong specificity. The results can be obtained in 15 minutes based on the high specificity of the dual antibody sandwich reaction principle and the emulsion immunochromatography analysis technique.

ASSAY PROCEDURE
1.Take out the sampling stick, inserted into the faeces sample, then put the sampling stick back, screw tight and shake well, repeat the action 3 times. Or using the sampling stick picked about 50mg faeces sample, and put in a faeces sample tube containing sample dilution, and screw tightly.

2.Use disposable pipette sampling take the thinner faeces sample from the diarrhea patient, then add 3 drops (about 100µL) to the fecal sampling tube and shake well, put aside.
3.Take out the test card from the foil bag, put it on the level table and mark it.
4.Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample verticaly and slowly into sample well of the card with provided dispette, start timing.
5.The result should be read within 10-15 minutes, and it is invalid after 15 minutes.
w

 


Product detail pictures:

High Performance Level Measuring Instruments - Diagnostic Kit(LATEX)for Antigen to Helicobacter Pylori – Baysen detail pictures

High Performance Level Measuring Instruments - Diagnostic Kit(LATEX)for Antigen to Helicobacter Pylori – Baysen detail pictures

High Performance Level Measuring Instruments - Diagnostic Kit(LATEX)for Antigen to Helicobacter Pylori – Baysen detail pictures


Related Product Guide:
Myeloid-related protein 8 induces self-tolerance and cross-tolerance to bacterial infection via TLR4- and TLR2-mediated signal pathways | Calprotectin Elisa Kit
MDxHealth (R): SelectMDx Cost-effective in Four European Countries Brussels Stock Exchange:MDXH | Calprotectin Elisa Kit

We're convinced that with joint endeavours, the business between us will bring us mutual benefits. We are able to guarantee you products high quality and competitive value for High Performance Level Measuring Instruments - Diagnostic Kit(LATEX)for Antigen to Helicobacter Pylori – Baysen , The product will supply to all over the world, such as: Sevilla, Chicago, Germany, We care about every steps of our services, from factory selection, product development & design, price negotiation, inspection, shipping to aftermarket. We have implemented a strict and complete quality control system, which ensures that each product can meet quality requirements of customers. Besides, all of our products have been strictly inspected before shipment. Your Success, Our Glory: Our aim is to help customers realize their goals. We are making great efforts to achieve this win-win situation and sincerely welcome you to join us.
  • Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Martina from Madrid - 2015.06.09 12:42
    This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Jack from Belize - 2016.11.11 11:41