Hot sale Factory Fluorescence Immunoassay Rapid Quantitative Test Machine - Diagnostic Kit (Colloidal Gold) for IgM/IgG Antibody to Dengue Virus – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

Assume full accountability to satisfy all demands of our consumers; reach ongoing advancements by endorsing the expansion of our purchasers; come to be the final permanent cooperative partner of clients and maximize the interests of clientele for Diagnostic Test Kits , Nt-Probnp , E2 Rapid Test Kit , Inspired by the rapid developing market of the fast food and beverage consumables all over the world , We are looking forward to working with partners/clients to make success together.
Hot sale Factory Fluorescence Immunoassay Rapid Quantitative Test Machine - Diagnostic Kit (Colloidal Gold) for IgM/IgG Antibody to Dengue Virus – Baysen Detail:

Diagnostic Kit (Colloidal Gold) for IgM/IgG Antibody to Dengue Virus
For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE

Diagnostic Kit(Colloidal Gold)for IgM/IgG Antibody to Dengue Virus is a colloidal gold immunochromatographic assay for the qualitative detection of IgM/IgG Antibody to Dengue Virus in human serum and plasma. This test is a screening reagent. All positive sample must be confirmed by other methodologies. This test is intended for healthcare professional use only.

PACKAGE SIZE
Twenty-five serving.

SUMMARY
Dengue Fever (Dengue Fever) is caused by Dengue virus infection. Dengue Fever is a group B vector virus and the yellow virus family flavivirus. Dengue virus antibody tests are often used enzyme-linked Immunoassay, Indirect Immunofluorescent Assay, Immunochromato – graphic Test. In recent years, with the development of the immune colloidal gold chromatography technology, using colloidal gold immune chromatography to detect serum (plasma) dengue virus antibody has become a reality. This method is characterized by simple operation, quick detection speed and saving manpower and material resources. It makes up for the inconveniences of ELISA and chemiluminescence method.

ASSAY PROCEDURE
1.Take out the test card from the foil bag, put it on the level table and mark it.

2.Use pipette to absorb sample 2ul, add it into sample well of the card;
3.Add 2 drops (80-100ul) sample diluent into sample well of the card;
4.The result should be read within 20 minutes.

TEST RESULTS AND INTERPRETATION[2]

 

Test results and interpretation

 u1 IgM/IgG positive: The magenta stripe appear in quality control line (C) , test line G and test line M, indicating that the sample contains dengue virus IgM/IgG antibody. 
 u1 IgG positive: The magenta stripe appear in quality control line (C) and test line G, indicating that the samples contain dengue virus IgG antibodies. 
 u1 IgM positive: The magenta stripe appear in quality control line (C) and test line M, indicating that the sample contains dengue virus IgM antibody.  
 u1 Negative: The magenta strip only appear in quality control line (C), test line G and test line M have no magenta stripe, indicating that the samples do not contain dengue virus IgM/IgG antibody or dengue virus IgM/IgG antibody in sample is below the detection level of the reagent. 
 u2Invalid: The magenta strip does not appear in quality control line (C), indicating improper operation or reagent failure, should be retested.

 


Product detail pictures:

Hot sale Factory Fluorescence Immunoassay Rapid Quantitative Test Machine - Diagnostic Kit (Colloidal Gold) for IgM/IgG Antibody to Dengue Virus – Baysen detail pictures


Related Product Guide:
Model suggests liquid biopsy improves prostate cancer outcomes, but that’s not the real world | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase
4K Test May Help Avert Unnecessary Prostate Cancer Treatment 3090D553-9492-4563-8681-AD288FA52ACE Group 2 34A8E98B-62ED-4216-98D6-E986304F4C2E | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase

The organization upholds the philosophy of "Be No.1 in good quality, be rooted on credit history and trustworthiness for growth", will keep on to provide previous and new customers from home and overseas whole-heatedly for Hot sale Factory Fluorescence Immunoassay Rapid Quantitative Test Machine - Diagnostic Kit (Colloidal Gold) for IgM/IgG Antibody to Dengue Virus – Baysen , The product will supply to all over the world, such as: India, UAE, USA, Over the years, with high-quality products, first- class service, ultra-low prices we win thee trust and favor of customers. Nowadays our products sell all over the domestic and abroad. Thanks for the regular and new customers support. We provide high quality product and competitive price, welcome the regular and new customers cooperate with us!
  • As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Adelaide from moldova - 2016.03.07 13:42
    This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Beatrice from Chicago - 2016.11.11 11:41