We strive for excellence, services the customers", hopes to be the top cooperation team and dominator business for personnel, suppliers and prospects, realizes benefit share and continual promotion for Chlamydia Home Test , Dengue Antigen , Renal Function Disease Urine Strip Tests , All products are manufactured with advanced equipment and strict QC procedures in order to ensure high quality. Welcome customers new and old to contact us for business cooperation.
Hot sale Factory One Step Rapid Test Helicobacter Pylori - Diagnostic kit for C-reative protein (CRP) Quantitative Cassette – Baysen Detail:

Diagnostic Kit for hypersensitive C-reactive protein

(fluorescence immunochromatographic assay)

For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE

Diagnostic Kit for hypersensitive C-reactive protein (fluorescence immunochromatographic assay) is a fluorescence immunochromatographic assay for the quantitative detection of C-reactive protein (CRP) in human serum /plasma/ Whole blood. It is a non-specific indicator of inflammation. All positive sample must be confirmed by other methodologies. This test is intended for healthcare professional use only.

SUMMARY

C-reactive protein is an acute phase protein produced by lymphokine stimulation of liver and epithelial cells. It exists in human serum, cerebrospinal fluid, pleural and abdominal fluid, etc., and is a part of non-specific immune mechanism. 6-8h after the occurrence of bacterial infection,CRP began to increase, 24-48h reached the peak, and the peak value could reach hundreds of times of normal. After the elimination of the infection, CRP dropped sharply and returned to normal within one week. However, CRP does not increase significantly in the case of viral infection, which provides a basis for the identification of early infection types of diseases, and is a tool for identifying viral or bacterial infections.

PRINCIPLE OF THE PROCEDURE

The membrane of the test device is coated with anti CRP antibody on the test region and goat anti rabbit IgG antibody on the control region. Lable pad are coated by fluorescence labeled anti CRP antibody and rabbit IgG in advance. When testing positive sample, the CRP antigen in sample combine with fluorescence labeled anti CRP antibody, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper, when complex passed the test region, it combined with anti CRP coating antibody, forms new complex. CRP level is positively correlated with fluorescence signal, and the concentration of CRP in sample can be detected by fluorescence immunoassay assay.

REAGENTS AND MATERIALS SUPPLIED

25T package components

Test card individually foil pouched with a desiccant 25T

Sample diluents 25T

Package insert 1

MATERIALS REQUIRED BUT NOT PROVIDED

Sample collection container,timer

SAMPLE COLLECTION AND STORAGE

  1. The samples tested can be serum, heparin anticoagulant plasma or EDTA anticoagulant plasma.
  2. According to standard techniques collect sample. Serum or plasma sample can be kept refrigerated at 2-8℃ for 7days and cryopreservation below -15°C for 6 months. Whole blood sample can be kept refrigerated at 2-8℃ for 3 days
  3. All sample avoid freeze-thaw cycles.

Product detail pictures:

Hot sale Factory One Step Rapid Test Helicobacter Pylori - Diagnostic kit for C-reative protein (CRP) Quantitative Cassette – Baysen detail pictures

Hot sale Factory One Step Rapid Test Helicobacter Pylori - Diagnostic kit for C-reative protein (CRP) Quantitative Cassette – Baysen detail pictures

Hot sale Factory One Step Rapid Test Helicobacter Pylori - Diagnostic kit for C-reative protein (CRP) Quantitative Cassette – Baysen detail pictures


Related Product Guide:
New Prostate Cancer Test Gets FDA Approval | Cpn-Igm
There’s no justification for claiming new blood test is ’94% accurate’ compared to PSA test for prostate cancer | Psa Test Cost

owing to very good support, a variety of high quality merchandise, aggressive costs and efficient delivery, we love an excellent name among the our clients. We are an energetic company with wide market for Hot sale Factory One Step Rapid Test Helicobacter Pylori - Diagnostic kit for C-reative protein (CRP) Quantitative Cassette – Baysen , The product will supply to all over the world, such as: Orlando, Georgia, Chile, Since our establishment, we keep on improving our products and customer service. We are able to provide you with a wide range of high quality hair products at competitive prices. Also we can produce different hair products according to your samples. We insist on high quality and reasonable price. Except this, we provide best OEM service. We warmly welcome OEM orders and customers all over the world to cooperate with us for mutual development in the future.
  • Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Claire from Sweden - 2015.06.03 10:17
    The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Bess from UK - 2016.09.09 10:18