Manufacturer of Magnetostrictive Level Meter - Diagnostic Kit(Colloidal Gold)for Human Chorionic Gonadotrophin – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

Having a sound small business credit score, outstanding after-sales services and modern manufacturing facilities, we've got earned an fantastic reputation among our buyers across the globe for Helicobacter Pylori Urea Breath Test Analyzer , Diagnositc Kit For Follicle Stimulating Hormone , Helicobacter Pylori Test Kit , Our enterprise insists on innovation to promote the sustainable advancement of organization, and make us become the domestic high-quality suppliers.
Manufacturer of Magnetostrictive Level Meter - Diagnostic Kit(Colloidal Gold)for Human Chorionic Gonadotrophin – Baysen Detail:

Diagnostic KitColloidal Goldfor Human Chorionic Gonadotrophin
For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE
Diagnostic Kit(Colloidal Gold)for Human Chorionic Gonadotrophin is a colloidal gold immunochromatographic assay for the qualitative detection of human chorionic gonadotropin (HCG) levels in human serum and urine, it is used for early pregnancy diagnosis This test is a screening reagent. All positive sample must be confirmed by other methodologies. This test is intended for healthcare professional use only.

PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 50 kits /box.

SUMMARY
HCG is a glycoprotein hormone secreted by the developing placenta after egg fertilization. HCG levels can be rapidly elevated in serum or urine as early as 1 to 2.5 weeks during pregnancy, and reach a peak in 8 week, than fall to medium level in 4 month, and maintained the level until the end of the pregnancy[1]. The Kit is a simple, visual qualitative test that detects HCG antigen in human serum or urine. The Diagnostic Kit is based on immunochromatography and can give a result within 15 minutes.

ASSAY PROCEDURE
1.Take out the test card from the foil bag, put it on the level table and mark it.

2.Discard the first two drops sample, add 3 drops (about 100μL) no bubble sample verticaly and slowly into sample well of the card with provided dispette, start timing.
3.The result should be read within 10-15 minutes, and it is invalid after 15 minutes.


Product detail pictures:

Manufacturer of Magnetostrictive Level Meter - Diagnostic Kit(Colloidal Gold)for Human Chorionic Gonadotrophin – Baysen detail pictures


Related Product Guide:
Routine prostate cancer testing ruled out due to ‘clear harms’ and ‘small’ benefit | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase
Evaluation of a New Immunochromatography Technology Test (LDBio Diagnostics) To Detect Toxoplasma IgG and IgM: Comparison with the Routine Architect Technique | P24 Test Strips

We always stick to the principle "Quality First, Prestige Supreme". We are fully committed to providing our clients with competitively priced quality products, prompt delivery and professional service for Manufacturer of Magnetostrictive Level Meter - Diagnostic Kit(Colloidal Gold)for Human Chorionic Gonadotrophin – Baysen , The product will supply to all over the world, such as: Poland, Mexico, Palestine, We have the best products and professional sales and technical team.With the development of our company, we are able to provide customers best products, good technical support, perfect after-sales service.
  • High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Agatha from Moldova - 2015.12.25 12:43
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Catherine from Paris - 2016.12.09 14:01