Manufacturer of Salt Corrosion Test Chamber - Diagnostic Kit(LATEX)for Rotavirus Group A – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

"Based on domestic market and expand overseas business" is our improvement strategy for Test Kit , Crp Rapid Test Kit , Hcv Test , We welcome you to join us in this path of creating a prosperous and efficient business together.
Manufacturer of Salt Corrosion Test Chamber - Diagnostic Kit(LATEX)for Rotavirus Group A – Baysen Detail:

Diagnostic KitLATEXfor Rotavirus Group A
For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE
Diagnostic Kit(LATEX)for Rotavirus Group A is suitable for qualitative detection of Rotavirus Group A antigen in human fecal samples. This test is intended for healthcare professional use only. Meanwhile, this test is used for the clinical diagnosis of infantile diarrhea in patients with Rotavirus Group A infection.

PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 50 kits /box.

SUMMARY
Rotavirus is classified as a rotavirus genus of the exenteral virus, which has a spherical shape with a diameter of about 70nm. Rotavirus contains 11 segments of double-stranded RNA. The rotavirus can be seven groups (a-g) based on antigenic differences and gene characteristics. Human infections of group A, group B and C group rotavirus have been reported. Rotavirus Group A is the important cause of severe gastroenteritis in children worldwide[1-2].

ASSAY PROCEDURE
1.Take out the sampling stick, inserted into the faeces sample, then put the sampling stick back, screw tight and shake well, repeat the action 3 times. Or using the sampling stick picked about 50mg faeces sample, and put in a faeces sample tube containing sample dilution, and screw tightly.

2.Use disposable pipette sampling take the thinner faeces sample from the diarrhea patient, then add 3 drops (about 100uL) to the fecal sampling tube and shake well, put aside.
3.Take out the test card from the foil bag, put it on the level table and mark it.
4.Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample verticaly and slowly into sample well of the card with provided dispette, start timing.
5.The result should be read within 10-15 minutes, and it is invalid after 15 minutes.
w

 


Product detail pictures:

Manufacturer of Salt Corrosion Test Chamber - Diagnostic Kit(LATEX)for Rotavirus Group A – Baysen detail pictures


Related Product Guide:
New blood test is more accurate in predicting prostate cancer risk than PSA: IsoPSA assay can help in determining the need for prostate biopsy for patients — ScienceDaily | P24 Test Strips
What Changed In The EV Industry In 2018? | Calprotectin Elisa Kit

Our commission is to serve our users and clients with best quality and competitive portable digital products for Manufacturer of Salt Corrosion Test Chamber - Diagnostic Kit(LATEX)for Rotavirus Group A – Baysen , The product will supply to all over the world, such as: Turkey, Swansea, Latvia, Our next goal is to exceed the expectations of every client by offering outstanding customer service, increased flexibility and greater value. All in all, without our customers we do not exist; without happy and fully satisfied customers, we fail. We are looking for the wholesale, Drop ship. Please contact us if you are interesting our products. Hope to do business with you all. High quality and fast shipment!
  • The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
    5 Stars By Althea from Los Angeles - 2016.09.09 10:18
    The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Kim from Argentina - 2016.09.28 18:29