OEM China Faecal Calprotectin Normal Range - Diagnostic Kit for Procalcitonin – Baysen
OEM China Faecal Calprotectin Normal Range - Diagnostic Kit for Procalcitonin – Baysen Detail:
Diagnostic Kit for Procalcitonin
Methodology:Fluorescence Immunochromatographic Assay
Production information
| Model Number | PCT | Packing | 25 Tests/ kit, 30kits/CTN |
| Name |
Diagnostic Kit for Procalcitonin |
Instrument classification | Class II |
| Features | High sensitivity, Easy opeation | Certificate | CE/ ISO13485 |
| Accuracy | > 99% | Shelf life | Two Years |
| Methodology | Fluorescence Immunochromatographic Assay | OEM/ODM service | Avaliable |
INTENDED USE
This kit is applicable to the in vitro quantitative detection on the content of procalcitonin (PCT) in human
serum/plasma/whole blood samples and is mainly used for implementing auxiliary diagnosis of clinical systemic
bacterial infection and sepsis. This kit only provides the test result of Procalcitonin, and the obtained result shall
be analyzed in combination with other clinical information.
Test procedure
| 1 | Before using the reagent,read the package insert carefully and familiarize yourself with the operating procedures. |
| 2 | Select standard test mode of WIZ-A101 portable immune analyzer |
| 3 | Open the aluminum foil bag package of reagent and take out the test device. |
| 4 | Horizontally insert the test device into the slot of immune analyzer. |
| 5 | On home page of operation interface of immune analyzer, click “Standard” to enter test interface. |
| 6 | Click “QC Scan” to scan the QR code on inner side of the kit; input kit related parameters into instrument and select sample type. Note: Each batch number of the kit shall be scanned for one time. If the batch number has been scanned, then skip this step. |
| 7 | Check the consistency of “Product Name”, “Batch Number” etc. on test interface with information on the kit label. |
| 8 | Take out sample diluent upon consistent information, add 80μL serum/plasma/whole blood sample, and thoroughly mix them; |
| 9 | Add 80µL aforesaid thoroughly mixed solution into well of test device; |
| 10 | After complete sample addition, click “Timing” and remaining test time will be automatically displayed on the interface. |
| 11 | Immune analyzer will automatically complete test and analysis when test time is reached. |
| 12 | After test by immune analyzer is completed, test result will be displayed on test interface or can be viewedthrough “History” on home page of operation interface. |
Note: each sample shall be pipetted by clean disposable pipette to avoid cross contamination.
Product detail pictures:
Related Product Guide:
Direct Reading of Bona Fide Barcode Assays for Diagnostics with Smartphone Apps | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase
Metabolic Signatures of Exercise in Human Plasma | Psa Test Cost
We retain improving upon and perfecting our items and repair. At the same time, we perform actively to do research and progress for OEM China Faecal Calprotectin Normal Range - Diagnostic Kit for Procalcitonin – Baysen , The product will supply to all over the world, such as: Seychelles, Ecuador, Swedish, The best and original quality for spare parts is a most important factor for transportation. We may stick on supplying original and good quality parts even a little profit earned. God will bless us to do kindness business forever.
This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!