OEM Customized Renal Function Disease Urine Strip Tests - procalcitonin rapid test kit lab test devices POCT Reagent – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

We always believe that one's character decides products' quality, the details decides products' quality ,with the REALISTIC,EFFICIENT AND INNOVATIVE team spirit for Tf Combo Test Kit , Progesterone Analyzer , Helicobacter Pylori Detector , Honesty is our principle, professional operation is our work, service is our goal, and customers' satisfaction is our future!
OEM Customized Renal Function Disease Urine Strip Tests - procalcitonin rapid test kit lab test devices POCT Reagent – Baysen Detail:

Products Parameters

3

PRINCIPLE AND PROCEDURE OF FOB TEST

PRINCIPLE

The membrane of the test device is coated with anti PCT antibody on the test region and goat anti rabbit IgG antibody on the control region. Lable pad are coated by fluorescence labeled anti PCT antibody and rabbit IgG in advance. When testing positive sample, the PCT antigen in sample combine with fluorescence labeled anti PCT antibody, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper, when complex passed the test region, it combined with anti PCT coating antibody, forms new complex. PCT level is positively correlated with fluorescence signal, and the concentration of PCT in sample can be detected by fluorescence immunoassay assay.

Test Procedure

Please read the instrument operation manual and package insert before testing.

1. Lay aside all reagents and samples to room temperature.
2. Open the Portable Immune Analyzer(WIZ-A101), enter the account password login according to the operation method of the instrument, and enter the detection interface.
3. Scan the dentification code to confirm the test item.
4. Take out the test card from the foil bag.
5. Insert the test card into the card slot, scan the QR code, and determine the test item.
6. Add 60μL serum or plasma sample into sample diluent, and mix well.
7. Add 80μL sample solution to sample well of the card.
8. Click the “standard test” button, after 15 minutes, the instrument will automatically detect the test card, it can read the results from the display screen of the instrument, and record/print the test results.
9. Refer to the instruction of Portable Immune Analyzer(WIZ-A101).

packing

You May like


Home used SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


WIZ-A101 Portable Immune Analyzer


WIZ-A101 Portable Immune Analyzer


6


Diagnostic Kit for Pro-brain Natriuretic Peptide to amino-terminal (Fluorescence Immunochromatographic Assay)

About Us

贝尔森主图_conew1

Xiamen Baysen Medical Tech limited is a high biological enterprise which devotes itself to filed of fast diagnostic reagent and integrates research and development, production and sales into a whole. There are many advanced research staffs and sales managers in the company, all of them are have rich working experience in china and international biopharmaceutical enterprise.

Certificate display

dxgrd


Product detail pictures:

OEM Customized Renal Function Disease Urine Strip Tests - procalcitonin rapid test kit lab test devices POCT Reagent – Baysen detail pictures

OEM Customized Renal Function Disease Urine Strip Tests - procalcitonin rapid test kit lab test devices POCT Reagent – Baysen detail pictures

OEM Customized Renal Function Disease Urine Strip Tests - procalcitonin rapid test kit lab test devices POCT Reagent – Baysen detail pictures

OEM Customized Renal Function Disease Urine Strip Tests - procalcitonin rapid test kit lab test devices POCT Reagent – Baysen detail pictures

OEM Customized Renal Function Disease Urine Strip Tests - procalcitonin rapid test kit lab test devices POCT Reagent – Baysen detail pictures

OEM Customized Renal Function Disease Urine Strip Tests - procalcitonin rapid test kit lab test devices POCT Reagent – Baysen detail pictures

OEM Customized Renal Function Disease Urine Strip Tests - procalcitonin rapid test kit lab test devices POCT Reagent – Baysen detail pictures


Related Product Guide:
There’s no justification for claiming new blood test is ’94% accurate’ compared to PSA test for prostate cancer | P24 Test Strips
New blood test is more accurate in predicting prostate cancer risk than PSA: IsoPSA assay can help in determining the need for prostate biopsy for patients — ScienceDaily | P24 Test Strips

Our merchandise are commonly recognized and reliable by customers and can meet constantly developing economic and social desires for OEM Customized Renal Function Disease Urine Strip Tests - procalcitonin rapid test kit lab test devices POCT Reagent – Baysen , The product will supply to all over the world, such as: kazan, Bogota, Malaysia, The credibility is the priority, and the service is the vitality. We promise we have now the ability to offer excellent quality and reasonable price items for customers. With us, your safety is guaranteed.
  • Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
    5 Stars By Mildred from Lahore - 2016.01.11 17:15
    In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
    5 Stars By Philipppa from US - 2015.02.21 12:14