OEM Supply Diagnostic Otoscope Set Kit Vet Instrument - Diagnostic Kit(Colloidal Gold)for IgM Antibody to Human Enterovirus 71 – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

Sticking for the belief of "Creating items of top of the range and creating buddies with people today from all over the world", we normally put the interest of shoppers in the first place for Hbv Hcv Test Kit , Hcv Elisa Test Kit , Chlamydia Test Strip , We fully welcome customers from all over the world to establish stable and mutually beneficial business relationships, to have a bright future together.
OEM Supply Diagnostic Otoscope Set Kit Vet Instrument - Diagnostic Kit(Colloidal Gold)for IgM Antibody to Human Enterovirus 71 – Baysen Detail:

Diagnostic Kit(Colloidal Gold)for IgM Antibody to Human Enterovirus 71
For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE
Diagnostic Kit(Colloidal Gold)for IgM Antibody to Human Enterovirus 71 is a colloidal gold immunochromatographic assay for the qualitative determination of IgM Antibody to Human Human Enterovirus 71(EV71-IgM) in human whole blood,serum or plasma.This test is a screening reagent. All positive sample must be confirmed by other methodologies.This test is intended for healthcare professional use only. 

PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 50 kits /box

Summary
EV71 is one of the main pathogens of hand, foot and mouth disease(HFMD), which can cause myocarditis, encephalitis,acute respiratory disease and other diseases except HFMD. The Kit is a simple, visual qualitative test that detects EV71-IgM in human whole blood, serum or plasma. The Diagnostic Kit is based on immunochromatography and can give a result within 15 minutes.

Applicable instrument
Except visual inspection, the kit can be matched with Continuous immune analyzer WIZ-A202 of Xiamen Wiz Biotech Co., Ltd 

ASSAY PROCEDURE
The WIZ-A202 test procedure see the instruction of Continuous immune analyzer. Visual test procedure is as follows

1.Take out the test card from the foil bag, put it on the level table and mark it.
2.Add 10μl serum or plasma sample or 20ul whole blood sample to sample well of the card with provided dispette, then add 100μl (about 2-3 drop) sample diluent; start timing
3.Wait for a minimum 10-15 minutes and read the result, the result is invalid after 15 minutes.

 


Product detail pictures:

OEM Supply Diagnostic Otoscope Set Kit Vet Instrument - Diagnostic Kit(Colloidal Gold)for IgM Antibody to Human Enterovirus 71 – Baysen detail pictures


Related Product Guide:
Tumor Suppressor p53 Stimulates the Expression of Epstein-Barr Virus Latent Membrane Protein 1 | Cpn-Igm
Benefits of PSA test to screen for prostate cancer are roughly equal to its harms, expert panel says | Cpn-Igm

We thinks what clients think, the urgency of urgency to act from the interests of a client position of theory, allowing for greater quality, lessen processing costs, price ranges are much more reasonable, won the new and outdated shoppers the support and affirmation for OEM Supply Diagnostic Otoscope Set Kit Vet Instrument - Diagnostic Kit(Colloidal Gold)for IgM Antibody to Human Enterovirus 71 – Baysen , The product will supply to all over the world, such as: Netherlands, Miami, Sri Lanka, Our tenet is "integrity first, quality best". Now we have confidence in providing you with excellent service and ideal merchandise. We sincerely hope we can establish win-win business cooperation with you in the future!
  • The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Eileen from Malta - 2015.10.01 14:14
    This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Emily from Eindhoven - 2016.02.14 13:19