Reliable Supplier Flexible Digital Thermometertemperature Thermometer - IgM antibody Enterovirus 71 EV71 rapid test kit EV 71 antiboday – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

We've got quite possibly the most state-of-the-art production gear, experienced and qualified engineers and workers, acknowledged top quality handle systems along with a friendly expert gross sales group pre/after-sales support for Thyroxine T4 , Creatine Kinase Test Kit , Renal Function Test Kit , And we can help looking for any products of the customers' needs. Make sure provide the best Service, the Best Quality, The fast Delivery.
Reliable Supplier Flexible Digital Thermometertemperature Thermometer - IgM antibody Enterovirus 71 EV71 rapid test kit EV 71 antiboday – Baysen Detail:

Products Parameters

3.EV-71-2

PRINCIPLE AND PROCEDURE OF FOB TEST

PRINCIPLE

The membrane of the test device is coated with anti EV71 antibody on the test region and goat anti rabbit IgG antibody on the control region. Lable pad are coated by fluorescence labeled anti EV71 antibody and rabbit IgG in advance. When testing positive sample, the EV71 antigen in sample combine with fluorescence labeled anti EV71 antibody, and form immune mixture. Under the action of the chromatography, the complex flow in the direction of absorbent paper, when complex passed the test region, it combined with anti EV71 coating antibody, forms new complex.

If it is negative, the sample does not contain enterovirus 71 IgM antibody, so that the immune complex cannot be formed. There will be no red line in the detection area (T). No matter whether Enterovirus 71 IgM antibody exists in the specimen or not, the remaining colloidal gold-labeled mouse anti-human IgM monoclonal antibody and the goat anti-mouse IgG antibody coated in the quality control area (C) binds. Then the agglutinates develop color in the quality control area, and the red line will appear in (C). The red line is the standard appears in the quality control area (C) for judging whether there are enough samples and whether the chromatography process is normal. It is also used as an internal control standard for reagents.

Test Procedure:

1.The samples tested can be whole blood, including venous blood or Peripheral blood. Whole blood cannot be stored after collecting. I should be used soon after collecting.

2.Serum samples are collected aseptically according to standard techniques. Heat-inactivated serum cannot use. It is not recommended to use lipemic, turbid or contaminated serum. Particulate matter in serum. And precipitation will affect the test results, such samples should be centrifuged or filtered before use.

3.The samples tested can be heparin, Sodium citrate or EDTA anticoagulant plasma.

4.According to standard techniques collect sample. Serum or plasma sample can be kept refrigerated at 2-8℃ for 3 days and cryopreservation below -15°C for 3 months.

5.All sample avoid freeze-thaw cycles.

packing

You May like


Home used SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


WIZ-A101 Portable Immune Analyzer


WIZ-A101 Portable Immune Analyzer


6.超级链接产品第三个产品的图片cpn-igm


Diagnostic Kit for Cardiac Troponin I (Fluorescence Immunochromatographic Assay)

About Us

贝尔森主图_conew1

Xiamen Baysen Medical Tech limited is a high biological enterprise which devotes itself to filed of fast diagnostic reagent and integrates research and development, production and sales into a whole. There are many advanced research staffs and sales managers in the company, all of them are have rich working experience in china and international biopharmaceutical enterprise.

Certificate display

dxgrd


Product detail pictures:

Reliable Supplier Flexible Digital Thermometertemperature Thermometer - IgM antibody Enterovirus 71 EV71 rapid test kit EV 71 antiboday – Baysen detail pictures

Reliable Supplier Flexible Digital Thermometertemperature Thermometer - IgM antibody Enterovirus 71 EV71 rapid test kit EV 71 antiboday – Baysen detail pictures

Reliable Supplier Flexible Digital Thermometertemperature Thermometer - IgM antibody Enterovirus 71 EV71 rapid test kit EV 71 antiboday – Baysen detail pictures

Reliable Supplier Flexible Digital Thermometertemperature Thermometer - IgM antibody Enterovirus 71 EV71 rapid test kit EV 71 antiboday – Baysen detail pictures

Reliable Supplier Flexible Digital Thermometertemperature Thermometer - IgM antibody Enterovirus 71 EV71 rapid test kit EV 71 antiboday – Baysen detail pictures

Reliable Supplier Flexible Digital Thermometertemperature Thermometer - IgM antibody Enterovirus 71 EV71 rapid test kit EV 71 antiboday – Baysen detail pictures

Reliable Supplier Flexible Digital Thermometertemperature Thermometer - IgM antibody Enterovirus 71 EV71 rapid test kit EV 71 antiboday – Baysen detail pictures


Related Product Guide:
Ezra raises $4M to diagnose cancer with MRIs, not painful biopsies | Psa Test Cost
Bolton will make money from player sales available to Phil Parkinson | Cpn-Igm

Being supported by an advanced and professional IT team, we could offer technical support on pre-sales & after-sales service for Reliable Supplier Flexible Digital Thermometertemperature Thermometer - IgM antibody Enterovirus 71 EV71 rapid test kit EV 71 antiboday – Baysen , The product will supply to all over the world, such as: Benin, kazakhstan, Bangladesh, The working experience in the field has helped us forged a strong relations with customers and partners both in domestic and international market. For years, our products and solutions have been exported to more than 15 countries in the world and have been widely used by customers.
  • In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
    5 Stars By Nora from Oslo - 2016.05.02 18:28
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Michaelia from Romania - 2015.10.31 10:02