Diagnostic Kit(Colloidal Gold)for Fecal Occult Blood
For in vitro diagnostic use only
Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.
INTENDED USE
Diagnostic Kit(Colloidal Gold)for Fecal Occult Blood (FOB) is a colloidal gold immunochromatographic assay for the qualitative determination of hemoglobin in human faeces, it acts as gastrointestinal bleeding auxiliary diagnosis reagent clinical diagnosis. This test is a screening reagent. All positive sample must be confirmed by other methodologies. This test is intended for healthcare professional use only. Meanwhile, this test is used for IVD, extra instruments are not needed.
PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 100 kits /box
SUMMARY
The slight bleeding of digestive tract disease give rise to FOB, so the detection of FOB has important value for gastrointestinal bleeding disease auxiliary diagnosis, it is available approach for screening digestive tract diseases. The kit is a simple, visual qualitative test that detects hemoglobin in human faeces, it has high detection sensitivity and strong specificity. The test is based on immunochromatography and can give a result within 15 minutes.
ASSAY PROCEDURE
1.Take out the sampling stick, inserted into the faeces sample, then put the sampling stick back, screw tight and shake well, repeat the action 3 times. Or using the sampling stick picked about 50mg faeces sample, and put in a faeces sample tube containing sample dilution, and screw tightly.
2.Use disposable pipette sampling take the thinner faeces sample from the diarrhea patient, then add 3 drops (about 100uL) to the fecal sampling tube and shake well, put aside.
3.Take out the test card from the foil bag, put it on the level table and mark it.
4Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample verticaly and slowly into sample well of the card with provided dispette, start timing.
5.For the test strip: take out the test strip from the foil bag, put it on the level table and mark it. Dip the end with arrow of the strip into the sample solution, start timing.
6.The result should be read within 10-15 minutes, and it is invalid after 15 minutes.
Product detail pictures:




Related Product Guide:
When PSA Is 4-10, phi Test Helps With Biopsy Decision 3090D553-9492-4563-8681-AD288FA52ACE Group 2 34A8E98B-62ED-4216-98D6-E986304F4C2E | Cpn-Igm
Inhibiting the immunoproteasome exacerbates the pathogenesis of systemic Candida albicans infection in mice | Cpn-Igm
Which has a positive and progressive attitude to customer's desire, our corporation constantly improves our merchandise quality to satisfy the desires of consumers and further focuses on safety, reliability, environmental demands, and innovation of Special Design for 6.8ghz Radar Level Sensor - Diagnostic Kit(Colloidal Gold)for Fecal Occult Blood – Baysen , The product will supply to all over the world, such as: Uruguay, Jamaica, Mumbai, With the intensified strength and more reliable credit, we are here to serve our customers by providing the highest quality and service, and we sincerely appreciate your support. We will endeavor to maintain our great reputation as the best products supplier in the world. If you have any questions or comments, please contact with us freely.

Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!