Special Design for Serum Amyloid A test kit - Pepsinogen I Pepsinogen II and Gastrin-17 Combo rapid test kit – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

we can offer high quality products, competitive price and best customer service. Our destination is "You come here with difficulty and we give you a smile to take away" for Chlamydia Rapid Test , Diagnostic Kit For Stimulating Hormone , Antibody Of Helicobacter Pylori , If you are looking for Good Quality at a good price and timely delivery. Do contact us.
Special Design for Serum Amyloid A test kit - Pepsinogen I Pepsinogen II and Gastrin-17 Combo rapid test kit – Baysen Detail:

Diagnostic Kit for Pepsinogen I/Pepsinogen II /Gastrin-17

Methodology:fluorescence immunochromatographic assay

Production information

Model Number G17/PGI/PGII Packing 25 Tests/ kit, 30kits/CTN
Name Diagnostic Kit for Pepsinogen I/Pepsinogen II /Gastrin-17 Instrument  classification Class II
Features High sensitivity, Easy opeation Certificate CE/ ISO13485
Accuracy > 99% Shelf life Two Years
Methodology fluorescence immunochromatographic assay OEM/ODM service Avaliable

INTENDED USE

This kit is applicable to the in vitro quantitative detection of concentration of Pepsinogen I (PGI), Pepsinogen II
(PGII) and Gastrin 17 in human serum/plasma/whole blood samples, to evaluate gastric oxyntic gland cell
function, gastric fundus mucosa lesion and atrophic gastritis. The kit only provides test result of Pepsinogen I
(PGI), Pepsinogen II (PGII) and Gastrin 17. The obtained result shall be analyzed in combination with other clinical
information. It must only be used by healthcare professionals.

Test procedure

 1  Before using the reagent,read the package insert carefully and familiarize yourself with the operating procedures.
2 Select standard test mode of WIZ-A101 portable immune analyzer.
3 Open the aluminum foil bag package of reagent and take out the test device.
4 Horizontally insert the test device into the slot of immune analyzer.
5 On home page of operation interface of immune analyzer, click “Standard” to enter test interface
6 Click “QC Scan” to scan the QR code on inner side of the kit; input kit related parameters into instrument and
select sample type.
Note: Each batch number of the kit shall be scanned for one time. If the batch number has been scanned, then
skip this step.
7 Check the consistency of “Product Name”, “Batch Number” etc. On test interface with information on the kit
label.
8 After information consistency is confirmed, take out sample diluents, add 80µL of serum/plasma/whole blood
sample, and sufficiently mix.
9 Add 80µL of above mixed solution into the sample hole of test device.
10 After complete sample addition, click “Timing” and remaining test time will be automatically displayed on the
interface.
11 Immune analyzer will automatically complete test and analysis when test time is reached.
12 Result calculation and display
After test by immune analyzer is completed, test result will be displayed on test interface or can be viewed
through “History” on home page of operation interface.
PGI-PGII-G17-1 Superiority

The kit is high accurate,fast and can be transported at room temperature.It’s easy to operate,the mobile phone app can assist in the interpretation of results and save them for easy follow-up.

Specimen type : serum/plasma/whole blood samples

Testing time:10-15mins

Storage:2-30℃/36-86℉

Methodology:Solid Phase

Feature:

•  High sensitive

•  result reading in 15 minutes

•  Easy operation

• 2 tests in one time

PGI-PGII-G17-4

QQ图片20230322140021

The Clinical Performance

Clinical evaluation performance of the product is assessed by collecting 200 clinical samples. Use the marketed kit of enzyme linked immunosorbent assay as the control reagent. Compare the PGI test results. Use linearity regression to investigate their comparability. Correlation coefficients of two tests are y = 0.964X + 10.382 and R=0.9763 respectively. Compare the PGII test results. Use linearity regression to investigate their comparability. Correlation coefficients of two tests are y = 1.002X + 0.025 and R=0.9848 respectively. Compare the G-17 test results. Use linearity regression to investigate their comparability. Correlation coefficients of two tests are y =0.983X + 0.079 and R=0.9864 respectively.


Product detail pictures:

Special Design for Serum Amyloid A test kit -  Pepsinogen I Pepsinogen II  and Gastrin-17 Combo rapid test kit  – Baysen detail pictures

Special Design for Serum Amyloid A test kit -  Pepsinogen I Pepsinogen II  and Gastrin-17 Combo rapid test kit  – Baysen detail pictures

Special Design for Serum Amyloid A test kit -  Pepsinogen I Pepsinogen II  and Gastrin-17 Combo rapid test kit  – Baysen detail pictures

Special Design for Serum Amyloid A test kit -  Pepsinogen I Pepsinogen II  and Gastrin-17 Combo rapid test kit  – Baysen detail pictures


Related Product Guide:
Akok Akok’s next chapter begins at UConn, as a walk-on — for now | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase
Endoscopias podrían evitarse con prueba de sangre oculta en heces – Química Clínica | P24 Test Strips

Our business has been focusing on brand strategy. Customers' pleasure is our best advertising. We also offer OEM company for Special Design for Serum Amyloid A test kit - Pepsinogen I Pepsinogen II and Gastrin-17 Combo rapid test kit – Baysen , The product will supply to all over the world, such as: Bangalore, South Africa, Hungary, Hard work to keep making progress, innovation in the industry, make every effort to first-class enterprise. We try our best to build the scientific management model, to learn abundant professional knowledge, to develop advanced production equipment and production process , to create the first-call quality products, reasonable price , high quality of service , quick delivery , to give you create new value .
  • The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Stephen from Sheffield - 2016.01.28 19:59
    Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
    5 Stars By Quintina from Puerto Rico - 2015.09.23 18:44