6 channel incubator temprature control for rapid test

short description:

6 channel incubator temprature control for rapid test


  • Testing time: 10-15 minutes
  • Valid Time: 24 month
  • Accurancy: More than 99%
  • Specification: 1/25 test/box
  • Storage temperature : 2℃-30℃
  • Channel: 6
  • Product Detail

    Product Tags

    6 channel incubator temprature control for rapid test

    Production information

    Model Number Incubator Packing 1 set/carton
    Name Incubator
    Instrument  classification Class I
    Features High sensitivity, Easy opeation Certificate ISO13485
    Accuracy > 99% Shelf life Two Years
    Weight 3KG OEM/ODM service Avaliable

     

    Test procedure

     1  Before using the reagent,read the package insert carefully and familiarize yourself with the operating procedures.
    2 Select standard test mode of WIZ-A101 portable immune analyzer
    3 Open the aluminum foil bag package of reagent and take out the test device.
    4 Horizontally insert the test device into the slot of immune analyzer.
    5 On home page of operation interface of immune analyzer, click “Standard” to enter test interface.
    6 Click “QC Scan” to scan the QR code on inner side of the kit; input kit related parameters into instrument and select sample type.
    Note: Each batch number of the kit shall be scanned for one time. If the batch number has been scanned, then skip this step.
    7 Check the consistency of “Product Name”, “Batch Number” etc. on test interface with information on the kit label.
    8  Take out sample diluent upon consistent information, add 80μL serum/plasma/whole blood sample, and thoroughly mix them;
    9  Add 80µL aforesaid thoroughly mixed solution into well of test device;
    10 After complete sample addition, click “Timing” and remaining test time will be automatically displayed on the interface.
    11 Immune analyzer will automatically complete test and analysis when test time is reached.
    12 After test by immune analyzer is completed, test result will be displayed on test interface or can be viewedthrough “History” on home page of operation interface.

    Note: each sample shall be pipetted by clean disposable pipette to avoid cross contamination.

    incubator

    Superiority

    The kit is high accurate,fast and can be transported at room temperature.It's easy to operate.
    Specimen type : Serum/Plasma/Whole Blood

    Testing time:10-15mins

    Storage:2-30℃/36-86℉

    Methodology:Fluorescence Immunochromatographic Assay

     

    Feature:

    •  High sensitive

    •  result reading in 15 minutes

    •  Easy operation

    •  temprature control,more accurate result

    •  High Accuracy 

     

    incubator

    You may also like:

    cTnI

    Diagnostic Kit for Cardiac Troponin I

    MYO

    Diagnostic Kit for Myoglobin

    D-Dimer

    Diagnostic Kit for D-Dimer


  • Previous:
  • Next: