Ikhithi yovavanyo olukhawulezayo lwe-HbA1C I-Glycosylated hemoglobin A1c Ikhithi yoVavanyo lwe-IVD yekhithi yovavanyo olukhawulezayo

inkcazelo emfutshane:

Inombolo yoMfanekiso HbA1c Ukupakisha 25 Iimvavanyo/ikhithi
Igama Ikhithi yokuxilonga iGlycosylated Hemoglobin A1c Ukuhlelwa kwesixhobo Udidi II
Iimbonakalo Uvakalelo oluphezulu, ukusebenza ngokulula Isatifikethi CE/ ISO13485
Umzekelo ilindle Beka ubomi kwishelufa Iminyaka emibini
Ukuchaneka > 99% Iteknoloji Ikhithi yobungakanani
Ugcino 2′C-30′C Uhlobo Izixhobo zokuHlalutya kwePathological


  • Ixesha lovavanyo:10-15 imizuzu
  • Ixesha elisebenzayo:Iinyanga ezingama-24
  • Ukuchaneka:Ngaphezulu kwe-99%
  • Inkcazo:1/25 uvavanyo / ibhokisi
  • Ubushushu bokugcina :2℃-30℃
  • Iinkcukacha zeMveliso

    Iithegi zeMveliso

    IiParameters zeeMveliso

    3Hba1c
    4-(2)
    4-(1)

    UMGAQO KUNYE NENKQUBO YOKUHLOLA FOB

    UMGAQO

    I-membrane yesixhobo sovavanyo igqunywe nge-anti-HbA1c antibody kwindawo yovavanyo kunye ne-anti-Hb antibody kwindawo yolawulo.Iphedi elayibhile iqatywe nge-fluorescence ebhalwe i-anti-Hb antibody kunye ne-anti-HbA1c antibody kwangaphambili.Xa kuvavanywa isampulu, i-antigen ye-HbA1c kwisampulu idibanisa ne-fluorescence ebhalwe i-anti-HbA1c antibody, i-antigen ye-Hb ekwisampulu idibanisa ne-fluorescence ebhalwe i-anti-Hb antibody kwaye yenza umxube wokuzivikela komzimba.Ngaphantsi kwesenzo se-immunochromatography, ukuhamba okuntsonkothileyo kwicala lephepha elifunxayo, xa i-complex iphumelele ummandla wovavanyo, idityaniswe ne-anti-HbA1c yokugquma i-antibody, yenza into entsha.xa i-complex idlulisa ummandla wokulawula, idibene ne-anti-Hb yokugquma i-antibody, yenza i-complex.

    Inkqubo yoVavanyo:

    Nceda ufunde incwadi yokusebenza kwesixhobo kunye nokufakwa kwephakheji phambi kovavanyo.

    1. Beka eceleni zonke ii-reagents kunye neesampuli kwiqondo lokushisa.
    2. Vula i-Portable Immune Analyzer (WIZ-A101), faka igama lokungena kwi-akhawunti ngokwendlela yokusebenza kwesixhobo, kwaye faka ujongano lokubona.
    3. Skena ikhowudi yokuchaza ukuze uqinisekise into yovavanyo.
    4. Khupha ikhadi lovavanyo kwibhegi yefoyile.
    5. Faka ikhadi lovavanyo kwi-slot yekhadi, skena ikhowudi ye-QR, kwaye unqume into yovavanyo
    6. Yongeza i-10μL Igazi elipheleleyo kwisampulu ye-diluent, vuthulula i-1 min kwaye udibanise kakuhle.
    7. Yongeza i-80μL yesisombululo sesampulu kwisampulu yequla lekhadi.
    8. Klikha iqhosha elithi "standard test", emva kwemizuzu eyi-15, isixhobo siya kubona ngokuzenzekelayo ikhadi lovavanyo, singakwazi ukufunda iziphumo kwiscreen sokubonisa sesixhobo, kwaye sirekhode/siprinte iziphumo zovavanyo.
    9. Jonga kumyalelo we-Portable Immune Analyzer (WIZ-A101).

    ukupakisha

    Ngathi

    贝尔森主图_conew1

    I-Xiamen Baysen Medical Tech limited lishishini eliphakamileyo lebhayoloji elizinikele ekufakeni i-reagent yokuxilonga ngokukhawuleza kwaye idibanise uphando kunye nophuhliso, imveliso kunye nokuthengisa kuyo yonke.Kukho uninzi lwabasebenzi bophando oluphambili kunye nabaphathi beentengiso kwinkampani, bonke banamava atyebileyo okusebenza eChina nakwishishini lamazwe ngamazwe le-biopharmaceutical.