Ikhithi yokuhlola okusheshayo ye-HbA1C i-Glycosylated hemoglobin A1c Test Kit IVD test kit

incazelo emfushane:

Inombolo Yemodeli I-HbA1c Ukupakisha Izivivinyo ezingu-25/ikhithi
Igama Ikhithi Yokuxilonga I-Glycosylated Hemoglobin A1c Ukuhlukaniswa kwezinsimbi Isigaba II
Izici Ukuzwela okuphezulu, Ukusebenza okulula Isitifiketi I-CE/ ISO13485
Isibonelo indle Isikhathi sokuphelelwa yisikhathi Iminyaka Emibili
Ukunemba > 99% Ubuchwepheshe Ikhithi yokulinganisa
Isitoreji 2′C-30′C Uhlobo Imishini Yokuhlaziya Izifo


  • Isikhathi sokuhlola:imizuzu eyi-10-15
  • Isikhathi Esivumelekile:Izinyanga ezingu-24
  • Ukunemba:Ngaphezu kuka-99%
  • Imininingwane:1/25 isivivinyo/ibhokisi
  • Izinga lokushisa lesitoreji:2℃ -30℃
  • Imininingwane Yomkhiqizo

    Amathegi Omkhiqizo

    Amapharamitha Emikhiqizo

    3Hba1c
    4-(2)
    4-(1)

    ISIMISO NENQUBO YOKUHLOLA I-FOB

    ISIMISO

    I-membrane yedivayisi yokuhlola imbozwe nge-anti HbA1c antibody esifundeni sokuhlola kanye ne-anti Hb antibody esifundeni sokulawula. I-lable pad imbozwe nge-anti Hb antibody ebhalwe nge-fluorescence kanye ne-anti HbA1c antibody kusengaphambili. Lapho kuhlolwa isampula, i-antigen ye-HbA1c kusampula ihlangana ne-anti HbA1c antibody ebhalwe nge-fluorescence, i-antigen ye-Hb kusampula ihlangana ne-anti Hb antibody ebhalwe nge-fluorescence bese yakha ingxube ye-immune. Ngaphansi kwesenzo se-immunochromatography, ukugeleza okuyinkimbinkimbi ohlangothini lwephepha elimuncayo, lapho i-complex idlula esifundeni sokuhlola, ihlangene ne-anti HbA1c coating antibody, yakha i-complex entsha. Lapho i-complex idlula esifundeni sokulawula, ihlangene ne-anti Hb coating antibody, yakha i-complex entsha. Izinga le-HbA1c lihlobene kahle nesignali ye-fluorescence, futhi ukuhlushwa kwe-HbA1c kanye ne-Hb kusampula kungatholakala nge-fluorescence immunoassay assay.

    Inqubo Yokuhlola:

    Sicela ufunde incwadi yemiyalelo yokusebenza kwethuluzi kanye nephakheji ngaphambi kokuhlola.

    1. Beka eceleni wonke ama-reagent namasampula endaweni yokushisa yegumbi.
    2. Vula i-Portable Immune Analyzer (WIZ-A101), faka ukungena ngemvume kwephasiwedi ye-akhawunti ngokwendlela yokusebenza kwethuluzi, bese ufaka isikhombikubona sokuthola.
    3. Skena ikhodi yokuqinisekisa ukuze uqinisekise into yokuhlola.
    4. Khipha ikhadi lokuhlola esikhwameni se-foil.
    5. Faka ikhadi lokuhlola embobeni yekhadi, skena ikhodi ye-QR, bese unquma into yokuhlolwa
    6. Faka i-10μL yegazi eliphelele ku-diluent yesampula, shukumisa umzuzu owodwa bese uxuba kahle.
    7. Engeza isisombululo sesampula esingu-80μL emthonjeni wesampula wekhadi.
    8. Chofoza inkinobho ethi "ukuhlolwa okujwayelekile", ngemva kwemizuzu eyi-15, ithuluzi lizobona ngokuzenzakalelayo ikhadi lokuhlola, lingafunda imiphumela esikrinini sokubonisa sethuluzi, bese liqopha/liphrinta imiphumela yokuhlolwa.
    9. Bheka imiyalelo ye-Portable Immune Analyzer (WIZ-A101).

    ukupakisha

    Mayelana NATHI

    贝尔森主图_conew1

    I-Xiamen Baysen Medical Tech Limited iyinkampani esezingeni eliphezulu lezinto eziphilayo ezizinikele ekufakweni kwe-reagent yokuxilonga okusheshayo futhi ihlanganisa ucwaningo nentuthuko, ukukhiqizwa kanye nokuthengisa kube yinto ephelele. Kunabasebenzi abaningi bocwaningo abaphambili kanye nabaphathi bezentengiso enkampanini, bonke banolwazi oluningi lokusebenza eShayina kanye nasemabhizinisini e-biopharmaceutical aphesheya kwezilwandle.