Ikhithi Yokuhlola I-Hepatitis B Virus Surface Antigent Test

incazelo emfushane:

Ikhithi yokuhlola i-Hepatitis B Surface Antigen Test Colloidal Gold

 


  • Isikhathi sokuhlola:imizuzu eyi-10-15
  • Isikhathi Esivumelekile:Izinyanga ezingu-24
  • Ukunemba:Ngaphezu kuka-99%
  • Imininingwane:1/25 isivivinyo/ibhokisi
  • Izinga lokushisa lesitoreji:2℃ -30℃
  • Indlela Yokwenza:Igolide le-Colloidal
  • Imininingwane Yomkhiqizo

    Amathegi Omkhiqizo

    Ukuhlolwa Okusheshayo Kwe-Hepatitis B Surface Antigen

    Indlela: Igolide le-Colloidal

    Ulwazi lokukhiqiza

    Inombolo Yemodeli Ama-HBsAg Ukupakisha Izivivinyo ezingu-25/ikhithi, amakhithi angu-30/i-CTN
    Igama Ikhithi Yokuhlola I-Hepatitis B Surface Antigen Test Ukuhlukaniswa kwezinsimbi Isigaba III
    Izici Ukuzwela okuphezulu, Ukusebenza okulula Isitifiketi I-CE/ ISO13485
    Ukunemba > 99% Isikhathi sokuphelelwa yisikhathi Iminyaka Emibili
    Indlela Yokwenza Igolide le-Colloidal Isevisi ye-OEM/ODM Kuyatholakala

     

    Inqubo yokuhlola

    Funda imiyalelo yokusebenzisa futhi uhambisane ngokuqinile nemiyalelo yokusebenzisa okudingekayo ukuze ugweme ukuthinta ukunemba kwemiphumela yokuhlolwa.

    1 Ngaphambi kokuhlolwa, ikhithi kanye nesampula kukhishwa esimweni sokugcina bese kulinganiswa nokushisa kwegumbi bese kuphawulwa.
    2 Udabula iphakethe lesikhwama se-aluminium foil, khipha idivayisi yokuhlola bese uyimaka, bese uyibeka ivundlile-etafuleni lokuhlola.
    3 thatha amaconsi amabili bese uwafaka emthonjeni onama-spiked;
    4 Umphumela kufanele uhunyushwe zingakapheli imizuzu eyi-15 ~ 20, futhi umphumela wokutholwa awusebenzi ngemuva kwemizuzu engama-20.

    Qaphela: isampula ngayinye kufanele ifakwe ngepayipi elihlanzekile elilahlwayo ukuze kugwenywe ukungcola okuhlukahlukene.

    UKUSETSHENZISWA Okuhlosiwe

    Le khithi yokuhlola ifanelekela ukuthola i-antigen ye-hepatitis B surface esezingeni eliphezulu kusampula yegazi lomuntu/i-plasma/igazi lonke e-in vitro, esetshenziselwa ukuxilongwa okusizayo kokutheleleka ngegciwane le-hepatitis B. Ukuhlolwa kabusha kufanele kuhlaziywe kuhlanganiswe nolunye ulwazi lwezokwelapha.

     

    I-HBsAg-1

    Ukuphakama

    Ikhithi inembile kakhulu, iyashesha futhi ingathuthwa ekushiseni kwegumbi, kulula ukuyisebenzisa

    Uhlobo lwesampula: Amasampula e-Seruam/Plasma/igazi eliphelele, kulula ukuwaqoqa amasampula

    Isikhathi sokuhlola: 10-15mins

    Isitoreji: 2-30℃/36-86℉

    Indlela: Igolide le-Colloidal

     

     

    Isici:

    • Ukuzwela okuphezulu

    • Ukunemba Okuphezulu

    • Ukusebenza okulula

    • Intengo eqondile yasefektri

    • Awudingi umshini owengeziwe ukuze ufunde imiphumela

     

    I-HBsAg-3
    umphumela wokuhlolwa

    Ukufundwa kwemiphumela

    Ukuhlolwa kwe-reagent ye-WIZ BIOTECH kuzoqhathaniswa ne-reagent yokulawula:

    Umphumela we-WIZ Umphumela Wokuhlola We-reagent Ebhekiselayo  Izinga elihle lokuhlangana kwezinto: 99.10% (95%CI 96.79%~99.75%)

    Izinga lokuhlangana okungalungile: 98.37%(95%CI96.24%~99.30%)

    Izinga lokuhlangana kwento yonke: 98.68% (95%CI97.30%~99.36%)

    Okuhle Okubi Isiyonke
    Okuhle 221 5 226
    Okubi 2 302 304
    Isiyonke 223 307 530

    Ungase futhi uthande: