Ikhithi yokuxilonga 25-(OH)VD TEST kit quantitative kit POCT reagent

incazelo emfushane:

Inombolo Yemodeli 25-(OH)VD Ukupakisha 25 Izivivinyo/ikhithi
Igama Ikhithi yokuxilonga 25-hydroxy Vitamin D Ukuhlukaniswa kwezinsimbi Ikilasi II
Izici Ukuzwela okuphezulu, ukusebenza okulula Isitifiketi CE/ ISO13485
Isifanekiso indle Impilo yeshelufu Iminyaka Emibili
Ukunemba > 99% Ubuchwepheshe Ikhithi yobuningi
Isitoreji 2′C-30′C Uhlobo Izinsiza Zokuhlaziya I-Pathological


  • Isikhathi sokuhlola:10-15 imizuzu
  • Isikhathi esivumelekile:Izinyanga ezingama-24
  • Ukunemba:Ngaphezu kuka-99%
  • Ukucaciswa:1/25 ukuhlolwa/ibhokisi
  • Izinga lokushisa lesitoreji :2℃-30℃
  • Imininingwane Yomkhiqizo

    Omaka bomkhiqizo

    Imikhiqizo Imingcele

    3.-vd
    4-(3)
    4-(4)

    ISIMISO NENKQUBO YOKUHLOLA I-FOB

    ISIMISO

    I-membrane yedivayisi yokuhlola ihlanganiswe ne-conjugate ye-BSA kanye ne-25-(OH)VD endaweni yokuhlola kanye ne-anti-rabbit IgG ye-antibody yembuzi endaweni yokulawula.Iphedi lomaka limbozwe nge-fluorescence mark anti 25-(OH)VD antibody kanye ne-rabbit IgG kusengaphambili.Lapho kuhlolwa isampula, i-25-(OH)VD kusampula ihlangana ne-fluorescence ephawulwe ukuthi i-anti 25-(OH)VD antibody, bese yenza ingxube yamasosha omzimba.Ngaphansi kwesenzo se-immunochromatography, ukugeleza okuyinkimbinkimbi kubheke ephepheni elimuncayo, lapho inkimbinkimbi idlula indawo yokuhlola, Umaka we-fluorescent wamahhala uzohlanganiswa no-25-(OH)VD kulwelwesi.Ukuhlushwa okungu-25-(OH) I-VD iwukuhlobana okunegethivu kwesignali ye-fluorescence, futhi ukugxila kwe-25-(OH)VD kusampula kungatholwa nge-fluorescence immunoassay assay.

    Inqubo Yokuhlola:

    Sicela ufunde imanuwali yokusebenza kwezinsimbi kanye nokufakwa kwephakheji ngaphambi kokuhlola.

    1. Beka eceleni wonke ama-reagents namasampuli ekamelweni lokushisa.
    2. Vula i-Portable Immune Analyzer(WIZ-A101), faka ukungena ngemvume kwephasiwedi ye-akhawunti ngokwendlela yokusebenza yensimbi, bese ufaka isixhumi esibonakalayo sokubona.
    3. Skena ikhodi yokuhlonza ukuze uqinisekise into yokuhlola.
    4. Khipha ikhadi lokuhlola esikhwameni se-foil.
    5. Faka ikhadi lokuhlola endaweni yekhadi, skena ikhodi ye-QR, bese unquma into yokuhlola.
    6. Faka i-serum engu-15μL noma isampula ye-plasma ibe isixazululo, uhlanganise kahle
    7. Engeza ingxube engu-80μL ukuze uthole isampula yomthombo wekhadi.
    8. Chofoza inkinobho "yokuhlola okuvamile", emva kwemizuzu engu-15, ithuluzi lizobona ngokuzenzakalelayo ikhadi lokuhlola, lingakwazi ukufunda imiphumela esikrinini sokubonisa sensimbi, futhi lirekhode/liphrinte imiphumela yokuhlolwa.
    9. Bheka imiyalelo ye-Portable Immune Analyzer(WIZ-A101).

    ukupakisha

    Mayelana NATHI

    贝尔森主图_conew1

    I-Xiamen Baysen Medical Tech limited iyibhizinisi eliphezulu lebhayoloji elizinikela ekufakweni kwe-reagent yokuxilonga esheshayo futhi ehlanganisa ucwaningo nentuthuko, ukukhiqizwa nokuthengisa kukonke.Kunezisebenzi eziningi ezithuthukile zocwaningo kanye nabaphathi bezokuthengisa enkampanini, bonke banokuhlangenwe nakho okucebile kokusebenza e-china kanye nebhizinisi lamazwe ngamazwe le-biopharmaceutical.