Ikhithi yokuhlola esheshayo ye-Pepsinogen I Pepsinogen II kanye ne-Gastrin-17 Combo

incazelo emfushane:

Ikhithi Yokuxilonga yePepsinogen I/Pepsinogen II/Gastrin-17
ukuhlolwa kwe-fluorescence immunochromatographic


  • Isikhathi sokuhlola:imizuzu eyi-10-15
  • Isikhathi Esivumelekile:Izinyanga ezingu-24
  • Ukunemba:Ngaphezu kuka-99%
  • Imininingwane:1/25 isivivinyo/ibhokisi
  • Izinga lokushisa lesitoreji:2℃ -30℃
  • Indlela Yokwenza:ukuhlolwa kwe-fluorescence immunochromatographic
  • Imininingwane Yomkhiqizo

    Amathegi Omkhiqizo

    Ikhithi Yokuxilonga yePepsinogen I/Pepsinogen II/Gastrin-17

    Indlela yokusebenza: ukuhlolwa kwe-fluorescence immunochromatographic

    Ulwazi lokukhiqiza

    Inombolo Yemodeli G17/PGI/PGII Ukupakisha Izivivinyo ezingu-25/ikhithi, amakhithi angu-30/i-CTN
    Igama Ikhithi Yokuxilonga yePepsinogen I/Pepsinogen II/Gastrin-17 Ukuhlukaniswa kwezinsimbi Isigaba II
    Izici Ukuzwela okuphezulu, Ukusebenza okulula Isitifiketi I-CE/ ISO13485
    Ukunemba > 99% Isikhathi sokuphelelwa yisikhathi Iminyaka Emibili
    Indlela Yokwenza ukuhlolwa kwe-fluorescence immunochromatographic Isevisi ye-OEM/ODM Kuyatholakala

    UKUSETSHENZISWA OKUHLOSIWE

    Le khithi iyasebenza ekutholakaleni kobuningi be-Pepsinogen I (PGI) ngaphakathi kwesibeletho, i-Pepsinogen II
    (PGII) kanye neGastrin 17 kumasampula egazi lomuntu/i-plasma/lonke, ukuhlola iseli le-gastric oxyntic gland
    umsebenzi, isilonda se-mucosa yesisu kanye ne-atrophic gastritis. Ikhithi inikeza kuphela umphumela wokuhlolwa kwe-Pepsinogen I
    (PGI), iPepsinogen II (PGII) kanye neGastrin 17. Umphumela otholiwe kufanele uhlaziywe kanye neminye imithi yokwelapha.
    ulwazi. Kumelwe lusetshenziswe ochwepheshe bezempilo kuphela.

    Inqubo yokuhlola

    1 Ngaphambi kokusebenzisa i-reagent, funda ngokucophelela iphakheji bese ujwayelana nezinqubo zokusebenza.
    2 Khetha imodi yokuhlola ejwayelekile ye-WIZ-A101 portable immune analyzer.
    3 Vula iphakethe lesikhwama se-aluminium foil eline-reagent bese ukhipha idivayisi yokuhlola.
    4 Faka idivayisi yokuhlola ngokuvundlile endaweni yokuhlaziya amasosha omzimba.
    5 Ekhasini lasekhaya le-interface yokusebenza ye-immune analyzer, chofoza okuthi “Standard” ukuze ufake i-interface yokuhlola
    6 Chofoza okuthi “QC Scan” ukuze uskene ikhodi ye-QR ngaphakathi kwekhithi; amapharamitha ahlobene nekhithi yokufaka kuthuluzi kanye
    khetha uhlobo lwesampula.
    Qaphela: Inombolo ngayinye yebhetshi yekhithi kufanele iskeniwe kanye. Uma inombolo yebhetshi isiskeniwe, khona-ke
    yeqa lesi sinyathelo.
    7 Hlola ukuvumelana “kwegama lomkhiqizo”, “inombolo yeqoqo” njll. Ku-interface yokuhlola nolwazi olukukhithi
    ilebula.
    8 Ngemva kokuqinisekiswa kokuhambisana kolwazi, khipha amasampula okuhlanza, engeza u-80µL we-serum/plasma/igazi lonke
    isampula, bese uxuba ngokwanele.
    9 Faka i-80µL yesisombululo esihlanganisiwe esingenhla emgodini wesampula wedivayisi yokuhlola.
    10 Ngemva kokwengeza isampula ephelele, chofoza okuthi “Isikhathi” bese isikhathi sokuhlola esisele sizoboniswa ngokuzenzakalelayo ku-
    isikhombikubona.
    11 I-immune analyzer izoqedela ngokuzenzakalelayo ukuhlolwa nokuhlaziywa lapho isikhathi sokuhlolwa sesifikile.
    12 Ukubalwa komphumela kanye nokuboniswa
    Ngemva kokuthi ukuhlolwa yi-immune analyzer sekuqediwe, umphumela wokuhlolwa uzoboniswa ku-interface yokuhlola noma ungabukwa
    ngokusebenzisa "Umlando" ekhasini lasekhaya le-interface yokusebenza.
    I-PGI-PGII-G17-1 Ukuphakama

    Ikhithi inembile kakhulu, iyashesha futhi ingathuthwa ekushiseni kwegumbi. Kulula ukuyisebenzisa, uhlelo lokusebenza lweselula lungasiza ekuchazeni imiphumela futhi luyigcine ukuze kube lula ukuyilandela.

    Uhlobo lwesampula: amasampula egazi eliphelele/i-plasma

    Isikhathi sokuhlola: 10-15mins

    Isitoreji: 2-30℃/36-86℉

    Indlela: Isigaba Esiqinile

    Isici:

    • Ukuzwela okuphezulu

    • ukufundwa kwemiphumela ngemizuzu eyi-15

    • Ukusebenza okulula

    • Ukuhlolwa okubili ngesikhathi esisodwa

    I-PGI-PGII-G17-4
    QQ图片20230322140021

    Ukusebenza Kwezokwelapha

    Ukusebenza kokuhlolwa komtholampilo komkhiqizo kuhlolwa ngokuqoqa amasampula omtholampilo angu-200. Sebenzisa ikhithi ethengiswayo ye-enzyme linked immunosorbent assay njenge-reagent yokulawula. Qhathanisa imiphumela yokuhlolwa kwe-PGI. Sebenzisa i-linearity regression ukuze uhlole ukuqhathanisa kwawo. Ama-coefficients okuhlobana kwezivivinyo ezimbili yi-y = 0.964X + 10.382 kanye ne-R=0.9763 ngokulandelana. Qhathanisa imiphumela yokuhlolwa kwe-PGII. Sebenzisa i-linearity regression ukuze uhlole ukuqhathanisa kwawo. Ama-coefficients okuhlobana kwezivivinyo ezimbili yi-y = 1.002X + 0.025 kanye ne-R=0.9848 ngokulandelana. Qhathanisa imiphumela yokuhlolwa kwe-G-17. Sebenzisa i-linearity regression ukuze uhlole ukuqhathanisa kwawo. Ama-coefficients okuhlobana kwezivivinyo ezimbili yi-y = 0.983X + 0.079 kanye ne-R=0.9864 ngokulandelana.

    Ungase futhi uthande:

    I-CAL

    Ikhithi Yokuxilonga yeCalprotectin(ukuhlolwa kwe-fluorescence immunochromatographic)

    I-HP-AG

    -Ikhithi Yokuxilonga ye-Antigen kuya ku-Helicobacter Pylori (Ukuhlolwa Kwe-Fluorescence Immunochromatographic)

    I-HP-AB

    Ikhithi Yokuxilonga Yokulwa Nomzimba Ku-Helicobacter Pylori (Ukuhlolwa Kwe-Fluorescence Immunochromatographic Assay


  • Okwedlule:
  • Olandelayo: