I-Pepsinogen I Pepsinogen II kanye nekhithi yokuhlola esheshayo ye-Gastrin-17 Combo

incazelo emfushane:

Ikhithi yokuxilonga ye-Pepsinogen I/Pepsinogen II/Gastrin-17
ukuhlolwa kwe-fluorescence immunochromatographic


  • Isikhathi sokuhlola:10-15 imizuzu
  • Isikhathi esivumelekile:Izinyanga ezingama-24
  • Ukunemba:Ngaphezu kuka-99%
  • Ukucaciswa:1/25 ukuhlolwa/ibhokisi
  • Izinga lokushisa lesitoreji :2℃-30℃
  • Indlela yokwenza:ukuhlolwa kwe-fluorescence immunochromatographic
  • Imininingwane Yomkhiqizo

    Omaka bomkhiqizo

    Ikhithi yokuxilonga ye-Pepsinogen I/Pepsinogen II/Gastrin-17

    Indlela yokwenza: i-fluorescence immunochromatographic assay

    Ulwazi lokukhiqiza

    Inombolo Yemodeli I-G17/PGI/PGII Ukupakisha 25 Ukuhlolwa/ikhithi, 30kits/CTN
    Igama Ikhithi yokuxilonga ye-Pepsinogen I/Pepsinogen II/Gastrin-17 Ukuhlukaniswa kwezinsimbi Ikilasi II
    Izici Ukuzwela okuphezulu, ukusebenza okulula Isitifiketi CE/ ISO13485
    Ukunemba > 99% Impilo yeshelufu Iminyaka Emibili
    Indlela yokwenza ukuhlolwa kwe-fluorescence immunochromatographic Isevisi ye-OEM/ODM Iyatholakala

    UKUSETSHENZISWA OKUHLOSIWE

    Le khithi isebenza ekutholweni komthamo we-in vitro wokuhlushwa kwe-Pepsinogen I (PGI), i-Pepsinogen II.
    (PGII) kanye ne-Gastrin 17 ku-serum yomuntu/i-plasma/amasampula egazi lonke, ukuhlola iseli ye-gastric oxyntic gland
    umsebenzi, isilonda se-gastric fundus mucosa kanye ne-atrophic gastritis.Ikhithi inikeza kuphela umphumela wokuhlola we-Pepsinogen I
    (PGI), Pepsinogen II (PGII) kanye ne-Gastrin 17. Umphumela otholiwe uzohlaziywa ngokuhambisana neminye imitholampilo.
    ulwazi.Kufanele isetshenziswe kuphela ochwepheshe bezempilo.

    Inqubo yokuhlola

    1 Ngaphambi kokusebenzisa i-reagent, funda iphakheji ngokucophelela futhi uzijwayeze nezinqubo zokusebenza.
    2 Khetha imodi yokuhlola evamile ye-WIZ-A101 ephathekayo yomzimba yokuhlaziya.
    3 Vula iphakheji yesikhwama se-aluminium foil ye-reagent bese ukhipha idivayisi yokuhlola.
    4 Faka ngokuvundlile idivayisi yokuhlola ku-slot ye-immune analyzer.
    5 Ekhasini lasekhaya le-interface yokusebenza ye-immune analyzer, chofoza okuthi "Standard" ukuze ufake isixhumi esibonakalayo sokuhlola
    6 Chofoza okuthi “QC Scan” ukuze uskene ikhodi ye-QR ohlangothini lwangaphakathi lwekhithi;okokufaka amapharamitha ahlobene nekhithi kuthuluzi kanye
    khetha uhlobo lwesampula.
    Qaphela: Inombolo ngayinye yeqoqo lekhithi izoskenwa ngesikhathi esisodwa.Uma inombolo ye-batch iskeniwe, ke
    yeqa lesi sinyathelo.
    7 Hlola ukuvumelana "Kwegama Lomkhiqizo", "Inombolo Yeqoqo" njll. Ekuhloleni ukusebenzelana nolwazi olukwikhithi
    ilebula.
    8 Ngemuva kokuqinisekiswa kokuvumelana kolwazi, khipha amasampula e-diluent, engeza u-80µL we-serum/plasma/igazi lonke.
    isampula, futhi uhlanganise ngokwanele.
    9 Engeza u-80µL wesixazululo esixubile esingenhla kumgodi wesampula wedivayisi yokuhlola.
    10 Ngemuva kokufakwa okuphelele kwesampula, chofoza "Isikhathi" futhi isikhathi sokuhlola esisele sizovezwa ngokuzenzakalelayo ku-
    esibonakalayo.
    11 I-immune analyzer izoqedela ukuhlola nokuhlaziya ngokuzenzakalelayo lapho isikhathi sokuhlolwa sesifinyelelwe.
    12 Isibalo somphumela nesibonisi
    Ngemuva kokuthi ukuhlolwa kwe-immune analyzer sekuqediwe, umphumela wokuhlolwa uzovezwa esibonakalayo sokuhlola noma ungabukwa
    ngokusebenzisa “Umlando” ekhasini lasekhaya lesixhumi esibonakalayo sokusebenza.
    PGI-PGII-G17-1 Ukuphakama

    Ikhithi inembe kakhulu, iyashesha futhi ingathuthwa ekamelweni lokushisa.Kulula ukuyisebenzisa, uhlelo lokusebenza lweselula lungasiza ekuchazeni imiphumela futhi luyilondolozele ukuyilandelela kalula.

    Uhlobo lwesampula: i-serum/plasma/amasampula egazi lonke

    Isikhathi sokuhlola: 10-15mins

    Isitoreji:2-30℃/36-86℉

    Indlela yokwenza:Isigaba Esiqinile

    Isici:

    • Ukuzwela okuphezulu

    • umphumela wokufunda emizuzwini eyi-15

    • Ukusebenza okulula

    • Izivivinyo ezi-2 ngesikhathi esisodwa

    PGI-PGII-G17-4
    QQ图片20230322140021

    Ukusebenza Kwemtholampilo

    Ukusebenza kokuhlolwa komtholampilo komkhiqizo kuhlolwa ngokuqoqa amasampula omtholampilo angama-200.Sebenzisa ikhithi ekhangisiwe ye-enzyme exhumene ne-immunosorbent assay njenge-reagent yokulawula.Qhathanisa imiphumela yokuhlolwa kwe-PGI.Sebenzisa ukuhlehla komugqa ukuze uphenye ukuqhathaniswa kwazo.Ama-coefficients okuxhumana okuhlola okubili ngu-y = 0.964X + 10.382 kanye no-R=0.9763 ngokulandelanayo.Qhathanisa imiphumela yokuhlolwa kwe-PGII.Sebenzisa ukuhlehla komugqa ukuze uphenye ukuqhathaniswa kwazo.Ama-coefficients okuxhumana okuhlola okubili ngu-y = 1.002X + 0.025 kanye no-R=0.9848 ngokulandelanayo.Qhathanisa imiphumela yokuhlolwa kwe-G-17.Sebenzisa ukuhlehla komugqa ukuze uphenye ukuqhathaniswa kwazo.Ama-coefficients okuxhumana okuhlola okubili ngu-y =0.983X + 0.079 kanye no-R=0.9864 ngokulandelanayo.

    Ungase futhi uthande:

    I-CAL

    Ikhithi yokuxilonga yeCalprotectin(ukuhlolwa kwe-fluorescence immunochromatographic)

    I-HP-AG

    -Ikhithi yokuxilonga ye-Antigen kuya ku-Helicobacter Pylori (I-Fluorescence Immunochromatographic Assay)

    I-HP-AB

    Ikhithi Yokuxilonga Ye-Antibody Ku-Helicobacter Pylori(I-Fluorescence Immunochromatographic Assay